14. [ ] From the ConnectHome configuration, determine the connections that are enabled:
/nas/sbin/nas_connecthome –i
15. [ ] For each enabled connection, verify that ConnectHome works:
/nas/sbin/nas_connecthome –test connection_name
For example:
/nas/sbin/nas_connecthome -t -email_1
or
/nas/sbin/nas_connecthome -t -email_2
or
/nas/sbin/nas_connecthome -t –https
or
/nas/sbin/nas_connecthome -t -modem_1
16. [ ] 4. Verify email notifications is configured:
/nas/bin/nas_emailuser –info
17. [ ] If the
Recipient Address(es)
field is empty, email notifications has not been configured and does
not need to be enabled. If you want to configure email notifications, use the
/nas/bin/nas_emailuser
command or Unisphere to configure it.
18. [ ] If the
Recipient Address(es)
field is populated, email notifications was enabled. Re-enable email
notifications:
a. Enable email notifications:
/nas/bin/nas_emailuser -modify -enabled yes
b. Verify that email notification works:
/nas/bin/nas_emailuser –info
c. Test the configuration and verify that the configured
Recipient Address(es)
received the test email:
/nas/bin/nas_emailuser –test
The array will now call home or responded to any other template applied to the VNX OE File array. Skip
over the next Block task to conclude the service activity.
Finish
19. [ ] Upon completion of this service activity, update the CSI database with the new VNX system
information for this site. Standard Global Services discipline requests you to register this service activity
in CSI, particularly for an Install or an Upgrade. You can use CRM or MS Outlook IB Database email
form in accordance with your team's reporting policy. Verify that all the customer site information is
correct (Table 7).