User Guide
–
Line Impedance Stabilization Network
7
2.0. Specification
MODEL
LN4-50N
Frequency Range
9kHz~30MHz
Power in/output
Terminal Type
Artificial Hand
220pF +510Ω
Supply Line/Phase
2 / 1
Network Inductance
50Ω/50uH + 5Ω + 250uH
Coupling Capacitor
0.25uF
Max. Current
100A
Max. Voltage
AC 250V
Power frequency
DC~60Hz
Output mode
Test, Analysis
RF output
BNC 50Ω
Dimension
W350 D530 H241 (mm)
Weight
28 kg
Environmental Specification
Installation
Indoor usage only
Operation Temperature/Humidity
+5 ~ 40
°
C /
20%~80% RH
Storage Temperature/Humidity
-20 ~ +65
°
C /
20%~80% RH
EMCIS’s Own Function
Test Mode
Line 1,2 (same as conventional LISN)
Analysis Mode Common-Mode and Differential-Mode
(used with EMCIS’ EMI Analyzer)