How to Use
How to Mute the sound (Fig.23)
1
2
With water running through the ionizer, press the "MELODY"
button.
All sounds except for the chime sounds will be muted.
You can adjust the volume with a small Phillips screw driver by
manipulating the Speaker Volume on the back of your ionizer.
Fig.23
Fig.24
Fig.26
Fig.27
Fig.28
Fig.29
Fig.30
Fig.31
Fig.33
How to Measure pH (Fig.24)
1
2
3
If the reagent and water are not mixed well, the correct result
may not be displayed.
Fill one of the test tubes provided about 1/4 full
with alkaline, acidic or purified water.
Drop 2 or 3 drops of the pH reagent into the container
and shake it.
The pH value is determined by matching the color the pH
color chart provided.
Important Note: Water quality and mineral content vary greatly in
different localities and will directly impact performance of your
ionizer with respect to pH.
Caution
DO NOT consume water containing reagent.
Keep the pH reagent liquid, color chart, and test tubes away from
direct sunlight.
KEEP pH reagent liquid AWAY FROM CHILDREN and
OPEN FLAMES!
For contact with eyes, flush liberally with fresh water, seek medical help
If ingested, induce vomiting, seek medical help.
Regularly check and clean your Pre-Filter
Fig.25
How to use the mineral port
There is a port at the top of your ionizer that is used for water
conditioning agents, i.e. the manufacture-supplied calcium or other
hard water conditioning agents.
1
2
3
4
Stop the water flow prior to opening the port.
Water will overflow if you open the port while water is flowing
Unscrew the cap and remove. [Fig. 26]
The first time you remove it the cap may be tight.
Use a butter knife to work it free.
Take the basket apart from the cap and dispose of the basket.
[Fig. 27]
NOTE: You will still see beads in the basket - they never
completely disappear.
It's the calcium coating on the beads that slowly releases into
the water. Beads will release calcium for about 1-2 months
depending on amount of useand pH of water.
5
Remove the plastic cap from the replacement basket.
Replace with the cap from the mineral port that you removed
in step 2. [Fig. 28]
Insert the basket into the calcium port and twist the cap closed.
- Water will overflow if you do not close the cap tightly.
1
2
How to set your individual pH levels
While pressing the MODE button on the front, turn the main
power switch on therear of the ionizer to the ON position. [Fig. 30]
You will hear a beep, and the default setting - Level 3 - will
appear on the pH level indicator [Fig. 31]
Press the Alkaline button to raise the setting, and press the
Acidic button to lower the setting.
[Fig. 32] (You can select a setting between 0 and 6)
3
4
Press the MODE button to save the setting. [Fig. 33]
Fig.32
Keeping the pre-filter clean is critical to the proper operation
of your ionizer.
With the water supply turned off, remove the pre-filter by pressing
on the end of the fitting and pulling out the hose at the same time.
Rinse the filter thoroughly from both sides to remove any built up
particulates.
Reinstall the filter.
Clean the filter in this way any time you notice a decreased flow
from your ionizer.
User can regulate the electrical current of the water ionizer based on
the water source.