“ P H   C O N T R O L L E R ”
O P E R A T I N G   M A N U A L

Read carefully!

ENGLISH Version

R1-10-02

This manual contains important safety informations about
installation and use of this equipment. Ignoring this
informations could result in injuries or damages.

It is strictly forbidden to use this equipment with
radioactive chemicals !

Summary of Contents for PH CONTROLLER

Page 1: ...refully ENGLISH Version R1 10 02 This manual contains important safety informations about installation and use of this equipment Ignoring this informations could result in injuries or damages It is strictly forbidden to use this equipment with radioactive chemicals ...

Page 2: ...ulations concerning the transport and storage of aggressive fluids When installing outside European Community always observe national regulations Manufacturer is not liable for any unauthorized use or misuse of this product that can cause injury or damage to persons or materials Caution Instrument must be accessible at all times for both operating and servicing Access must not be obstructed in any...

Page 3: ...ex GENERALDESCRIPTION 4 CONTROLPANEL 4 MENU FUNCTIONS 5 INSTRUMENTCALIBRATION 5 INSTRUMENT MESSAGES 5 FUSEREPLACEMENT 6 PERISTALTIC PUMPINTERNALHOSE 6 ON OFF INSTRUMENT 6 pH INSTRUMENTINSTALLATION DRAWING 7 ...

Page 4: ...275x220x140mm CONTROL PANEL Use UP and DOWN keys to select or to increase decrease set values The Enter key confirms your choice when this function is selected the led is on ESC key deletes the selection and returns to previous menu If you will use default values confirm it by pressing E Introduction Suction Hose to the chemical Delivery Hose to the swimmingpool Plant Peristaltic Capacity 2 2 l h ...

Page 5: ...efore the pump starts working The display will show the remaining working time At the end display 000 th instrument will stop the dosage To repeat another manual dosing cycle press E key press P to exit from the menu and cancel the operation pH pH chemical type used to restore the swimming pool pH value Set on bAS by UP and DOWN keys if using a pH chemical Set on ACd if using a pH chemical Press E...

Page 6: ... the corners of the panel Locate the fuse holder as shown on figure Remove the protective cap and replace the fuse with one of the same features 250V T315mA 5x20 PERISTALTIC PUMP INTERNAL HOSE REPLACEMENT Once a year or each 300 working hour replace the internal hose of the peristaltic pump ON OFF INSTRUMENT Keep pressed E key for about three seconds the instrument will be on off ...

Page 7: ...n valve 2 Sampling point 3 pH probe 4 Probe holder 5 pH instrument 7 Foot filter 8 Power cable 9 Safety breaker 10 Filter 11 Delivery hose 12 Suction hose 9 5 3 1 2 7 4 8 10 11 12 pH instrument installation drawing ...

Page 8: ...rialtypesandsendthemaccordingtolocalrecyclingdisposalrequirements We appreciate your efforts in supporting your local Recycle Environmental Program Working together we ll form an active union to assure the world s invaluable resources are conserved ...