39
MLQ mode.
Dosing rate is determined by pulses from a water meter on the base of set MLQ (milliliters
per quintal), chemical product concentration (%) and quantity for each single stroke set
during program session.
Which parameters must be set ?
MLQ (product quantity in milliliters per quintal)
CONC (% of product’s concentration): set 100% if product is pure
CC/STROKE (refer to CC/ST setup)
WMETER (water meter)
TIMEOUT
23. “MLQ” working mode
mode [06]
MLQ
MLQ
03.00
key
E
conc %
010.0
key
E
Use
“UP”
key to change selected unit (“_” blinking cursor) of MLQ.
To move on next digit press
“RIGHT”
key.
To modify quantity of product concentration press
“E”
key.
Use
“UP”
key to change selected unit (“_” blinking cursor) of CONC%.
To move on next digit press
“RIGHT”
key.
Press
“E”
key to save data and “
ESC
” to exit to main menu. Otherwise press
“ESC”
to discard data and exit to main menu.
Note: before to use this mode we suggest to set the “TIMEOUT” parameter.
“TIMEOUT” take part when the result is a multiplication.