23. “mA” working mode
mA mode.
Current from an external device drives the pump that doses proportionally using a minimum
and maximum of strokes for minute set during program session.
Which parameters must be set ?
HImA (maximum current)
LOmA (minimum current)
SPM (strokes per minute)
mode [09]
m
a
hi
m
a
10.0
spm: 100
Key
E
lo
m
a
00.0
spm: 000
Key
E
Key
ESC
To work in this mode is necessary to specify the “HImA” (maximum working current), “LOmA” (minimum working current) and “SPM” (strokes
per minute) values that pump will produce between the parameters.
To setup this values enter into “mA” mode. The cursor will blink on first digit (“HImA” field). Insert maximum current value that will be supplied
to the pump (
“UP”
key). To move on next digit press
“RIGHT”
key.
The cursor will blink on “SPM” field. Insert strokes per minute that pump will produce near “HImA” value (
“UP”
key). To move on next digit
press
“RIGHT”
key.
Press
“E”
key to move on “LOmA”.
The cursor will blink on first digit (“LOmA” field). Insert minimum current value that will be supplied to the pump (
“UP”
key). To move on next
digit press
“RIGHT”
key.
The cursor will blink on “SPM” field. Insert strokes per minute that pump will produce near “LOmA” value (
“UP”
key). To move on next digit
press
“RIGHT”
key.
Press
“E”
key to save data and “
ESC
” to exit to main menu. Otherwise press
“ESC”
to discard data and exit to main menu.
Attention
: if a wrong data is set (for example, it has been set the same value for HIV and LOV) an error message (WRONG ENTRY) will appear.