49
B Appendix. Construction Materials and Technical info
TECHNICAL FEATURES
Power supply:
230 VAC (190÷265 VAC)
Power supply:
115 VAC (90÷135 VAC)
Power supply:
24 VAC (20÷32 VAC)
Power supply:
12 VDC (10÷16 VDC)
Pump Strokes:
0 ÷ 180
Suction Height:
1,5 metres
Environment Temperature:
0 ÷ 45°C (32 ÷ 113°F)
Chemical Temperature:
0 ÷ 50°C (32 ÷ 122°F)
Installation Class:
II
Pollution Level:
2
Audible Noise:
74dbA
Packaging and Transporting Temperature:
-10 ÷ 50°C (14 ÷ 122°F)
Protection degree:
IP 65
MANUFACTURING MATERIALS
Case:
PPO
Pump head: PVDF
Diaphragm: PTFE
Balls:
CERAMIC, GLASS, PTFE, SS *
Suction Pipe PVC
Delivery Pipe: PE
Valve Body:
PVDF
O-ring:
FP, EP, WAX, SI, PTFE *
Injection connector
PP, PVDF (ceramic, HASTELLOY C276 spring)
Level Probe:
PP, PVDF *
Level probe cable:
PE
Foot Filter:
PP, PVDF *
* as ordered.
INFORMATION
Model
Flow
Stroke
capacity
Stroke
per min
Max pressure
Max Current
Hoses
Pump
Head
max l/h
Max
GPH
230 VAC
115 VAC
bar
PSI
2001
01
0,26
0,09
180
20
290
2.3
1.45
4 x 8
j
1802
02
0,53
0,19
180
18
261
2.3
1.45
4 x 6
k
1804
04
1,06
0,37
180
18
261
3.2
1.9
4 x 6
k
1502
02
0,53
0,19
180
15
218
2.7
1.3
4 x 6
k
1504
04
1,06
0,37
180
15
218
2.7
1.45
4 x 6
k
1505
05
1,32
0,46
180
15
218
3.2
1.9
4 x 6
k
1004
04
1,06
0,37
180
10
145
2.7
1.3
4 x 6
k
1005
05
1,32
0,46
180
10
145
2.7
1.45
4 x 6
k
1010
10
2,64
0,93
180
10
145
3.2
1.9
4 x 6
k
0706
06
1,59
0,56
180
07
102
2.7
1.3
4 x 6
k
0510
10
2,64
0,93
180
05
73
2.7
1.45
4 x 6
k
0512
12
3,17
1,11
180
05
73
3.2
1.9
4 x 6
k
0408
08
2,11
0,74
180
04
58
2.7
1.3
4 x 6
k
0310
10
2,64
0,93
180
03
44
2.7
1.3
4 x 6
k
0217
17
4,49
1,57
180
02
29
3.2
1.9
6 x 8
k
0116
16
4,23
1,48
180
01
15
2.7
1.45
6 x 8
k
Summary of Contents for VMS MF