10
CONTROL PANEL INSTRUCTIONS
FOR BALBOA 2-PUMP SYSTEM
Jets 1 & Jets 2 Keys
Press Jets to turn the pump on or off, and to
shift between low and high speeds. If left
running, the pump will turn off after 2 hours
on low speed, and turn off after 15 minutes
on high speed. Low speed may run
automatically at times, during which it cannot
be deactivated from the panel, but high speed
may be operated.
Light Key
Press Light to operate the spa light. Press a
second time to turn light off. A built-in timer
automatically turns light off after 4 hours, unless
it has been manually deactivated first.
The “Light” indicator lights up when light is on.
Temp Key
Press the Temp key once to display the set
temperature. To change the set temperature,
press the temperature button again before
the display stops flashing. Each press of the
button will continue to either raise or lower
the set temperature. If the opposite direction
is desired, allow the display to revert to the
current water temperature. Press the button
to display the set temperature, and again to
make the temperature change in the desired
direction.
After three seconds, the display will stop
flashing and begin to display the current spa
temperature.
Initial start-up
Programming the filter cycles
Water temperature Control (80
°F - 104°F / 26°C - 40°C)
The last measured water temperature is constantly displayed. The water tem-
perature displayed is current only when the pump has been running for at least
2 minutes.
Your spa will enter Priming Mode
when it is energized. During Priming
Mode, press “Jets” button repeatedly and be sure the pump is free of air.
Priming Mode lasts less than 5 minutes. Press the “Temp” button to exit. After
Priming Mode, the spa will run in Standard Mode (see Mode Programming
section).
Pump 1 low-speed is responsible for heating and filtration, and will be referred
to simply as the pump.
In multi-button sequences, if the buttons are pressed too quickly in sequence,
they may not register.
Spa functions
The first preset filter cycle begins 6 minutes after the spa is energized. The
second preset filter cycle begins 12 hours later.
Filter duration is programmable for 1, 2, 3, 4, 5, 6, 7, or 8 hours.
The default filter time is 1 hour.
To program, press “Warm” or “Cool,” then “Jets”. Press “Warm” or “Cool”
to adjust. Press “Jets” to exit programming.
Mode Programming
By default, your spa pack has been configured to operate in Standard Mode
only. Contact your dealer for instructions on how to enable mode changes.
Once the spa pack has been configured to allow mode changes, press
“Temp” then “Light” to switch to a different mode setting.
Standard Mode maintains set temperature.
will be displayed momentarily
when you switch into Standard Mode.
Economy Mode heats the spa to the set temperature only during filter cycles.
will display when water temp is not current, and will alternate with water
temp when the pump is running.
Sleep Mode heats the spa to within 20
°F/10°C of the set temperature only
during filter cycles.
will display when water temp is not current, and
will alternate with water temp when the pump is running.