background image

 

10 

 

CONTROL PANEL INSTRUCTIONS 

FOR BALBOA 2-PUMP SYSTEM 

Jets 1 & Jets 2 Keys 

 

Press Jets to turn the pump on or off, and to 

shift between low and high speeds. If left 

running, the pump will turn off after 2 hours 

on low speed, and turn off after 15 minutes 

on high speed. Low speed may run 

automatically at times, during which it cannot 

be deactivated from the panel, but high speed 

may be operated.  

Light Key 

 

Press Light to operate the spa light. Press a 

second time to turn light off. A built-in timer 

automatically turns light off after 4 hours, unless 

it has been manually deactivated first. 

 

 

The “Light” indicator lights up when light is on. 

 

Temp Key 

 

Press the Temp key once to display the set 

temperature. To change the set temperature, 

press the temperature button again before 

the display stops flashing. Each press of the 

button will continue to either raise or lower 

the set temperature. If the opposite direction 

is desired, allow the display to revert to the 

current water temperature. Press the button 

to display the set temperature, and again to 

make the temperature change in the desired 

direction. 

After three seconds, the display will stop 

flashing and begin to display the current spa 

temperature. 

 

Initial start-up 

Programming the filter cycles 

Water temperature Control (80

°F - 104°F / 26°C - 40°C)

 

 

The last measured water temperature is constantly displayed. The water tem-

perature displayed is current only when the pump has been running for at least 

2 minutes. 

Your spa will enter Priming Mode   

when it is energized. During Priming 

Mode, press “Jets” button repeatedly and be sure the pump is free of air

Priming Mode lasts less than 5 minutes. Press the “Temp” button to exit. After 

Priming Mode, the spa will run in Standard Mode (see Mode Programming 

section). 

 

Pump 1 low-speed is responsible for heating and filtration, and will be referred 

to simply as the pump.  

 

In multi-button sequences, if the buttons are pressed too quickly in sequence, 

they may not register. 

Spa functions 

The first preset filter cycle begins 6 minutes after the spa is energized. The 

second preset filter cycle begins 12 hours later.  

 

Filter duration is programmable for 1, 2, 3, 4, 5, 6, 7, or 8 hours. 

The  default filter time is 1 hour. 

 

To program, press “Warm” or “Cool,” then “Jets”. Press “Warm” or “Cool” 

to adjust. Press “Jets” to exit programming. 

Mode Programming 

By default, your spa pack has been configured to operate in Standard Mode 

only. Contact your dealer for instructions on how to enable mode changes. 

 

Once the spa pack has been configured to allow mode changes, press 

“Temp” then “Light” to switch to a different mode setting. 

 

Standard Mode maintains set temperature.  

will be displayed momentarily 

when you switch into Standard Mode.  

 

Economy Mode heats the spa to the set temperature only during filter cycles.  

will display when water temp is not current, and will alternate with water 

temp when the pump is running. 

 

Sleep Mode heats the spa to within 20

°F/10°C of the set temperature only 

during filter cycles.  

will display when water temp is not current, and 

will alternate with water temp when the pump is running.

 

Summary of Contents for Energize EM5

Page 1: ...Owner s Manual 2012 Important Information Enclosed Please read before setting up or using your spa Rev 1 1 12 MODELS EM5 EM6...

Page 2: ...o use this product unless they are closely supervised at all times 8 A wire connector is provided on this unit to connect a minimum No 8 AWG 8 4mm2 solid copper conductor between this unit and any met...

Page 3: ...WARNING Improper electrical connections or conductor sizing may cause the equipment module to operate improperly create the potential for an electrical hazard and may void the warranty 9 CAUTION Use o...

Page 4: ...ed on a solid flat and level surface that does not move or shake 7 You should consult with a builder or engineer to determine if your floor will support the spa weight Remember you must allow for the...

Page 5: ...ectrical Code N E C and local code requirements The connection must include the conductors necessary for operation and bonding as required by N E C 1 Remove the spa from its shipping container and ret...

Page 6: ...ent module area for water leaks If there is water dripping it is probably a loose connection at the equipment module You should re check the tightness of the fittings and placement of the O rings Chec...

Page 7: ...ou must properly test and maintain your spa water for health and appearance reasons Chemical imbalance can cause skin irritations and dirty water is both unsightly and undesirable to soak in With litt...

Page 8: ...e surface Bug Tar Remover or OOPS Do not use an abrasive brush or cleaning agent as it will scratch the finish DO NOT USE any of the following items to clean your tub Acetone Goof Off or any cleaners...

Page 9: ...sure that the thermostat is set to keep the water warm If you intend on closing down your spa for the winter you should follow the winterizing procedures listed below 1 Drain the spa as explained in t...

Page 10: ...ng for at least 2 minutes Your spa will enter Priming Mode when it is energized During Priming Mode press Jets button repeatedly and be sure the pump is free of air Priming Mode lasts less than 5 minu...

Page 11: ...rrent water temperature will be displayed DO NOT ENTER THE WATER Remove the spa cover and allow water to cool Once the heater has cooled reset by pushing any button If spa does not reset shut off the...

Page 12: ...l hot water coming from the jets Make sure all valves are open to allow full water flow through the system Limited water flow will NOT build enough pressure to allow the heater to come on Clean the fi...

Page 13: ...________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ________...

Page 14: ...an 49512 phonenumber 800 766 7727 for packaging and shipping instructions In addition Emerald reserves the right to inspect or designate a person to inspect any part that is claimed to be defective an...

Page 15: ...years unless otherwise excluded as described above from initial start up of spa and labor is not included on such parts notwithstanding anything above to the contrary The stainless steel escutcheon o...

Reviews: