A standard removable power distribution box provides flexibility when installing

the UPS. Optional power distribution boxes are available with a built-in

maintenance bypass switch that allows hot-swapping of the entire UPS.

PD-HDWR-MBS
Includes bypass
Input: hardwire
Output: hardwire

PD-006
Includes bypass
Input: L14-30
Output: (4) L5-20
(2) L6-30

PD-005
Includes bypass
Input: L14-30
Output: (4) L5-20
(2) L5-30

PD-HDWR 
Input: hardwire
Output: hardwire

PD-002
Includes bypass
Input: L14-30
Output: (2) 5-15/20
(2) L6-20

PD-003
Includes bypass
Input: L14-30
Output: (4) 5-15/20
(2) L6-30

6 kVA Power Output Distribution Options

168997_SL23172:15615 govern  7/22/08  2:28 PM  Page 7

Summary of Contents for 10 kVA

Page 1: ...AC Power For Business Critical Continuity Liebert GXT2 6 kVA 10 kVA UPS Rack Tower Configurable UPS For Network Protection 168997_SL23172 15615 govern 7 22 08 2 27 PM Page 2 ...

Page 2: ...2 Compact UPS Systems For High Power Network Rack Applications Liebert GXT2 10 kVA 168997_SL23172 15615 govern 7 22 08 2 28 PM Page 3 ...

Page 3: ...fier Charger Dual Voltages For Multiple Applications Simultaneous output voltages of 240 120 208 120 230 115 220 110 or 200 100 VAC provide the flexibility to adapt to multiple load requirements without the need to add additional transformers that take up extra space and add weight Input power factor correction to 0 98 reduces current harmonics and their heating effects Today s converged networks ...

Page 4: ...use of removable power distribution boxes that simply plug into the rear of the UPS The standard box provides terminal blocks for hardwired input and output connections An optional hardwire version that includes a maintenance bypass switch is also available When the ease of plug and play power connections is desired optional versions of the power distribution box convert the Liebert GXT2 6 kVA to ...

Page 5: ...een the UPS and a server and ensures a graceful unattended shutdown Built in closure signals Provides notification to monitoring systems of operating conditions including on battery low battery battery mode shutdown and any mode shutdown Emergency Power Off EPO Terminal connections for a normally open or normally closed emergency power off switch Other Product Features Of The New Liebert GXT2 6 kV...

Page 6: ...D HDWR MBS Includes bypass Input hardwire Output hardwire PD 006 Includes bypass Input L14 30 Output 4 L5 20 2 L6 30 PD 005 Includes bypass Input L14 30 Output 4 L5 20 2 L5 30 PD HDWR Input hardwire Output hardwire PD 002 Includes bypass Input L14 30 Output 2 5 15 20 2 L6 20 PD 003 Includes bypass Input L14 30 Output 4 5 15 20 2 L6 30 6 kVA Power Output Distribution Options 168997_SL23172 15615 go...

Page 7: ...n select output voltage in a range from 220 240V These units only require 5U of rack space and include internal batteries and charger Internal batteries provide approximately seven minutes of runtime at full load Both models include an automatic and manual internal bypass The standard configuration provides terminals for hardwired connections for the input and output as well as two IEC320 C19 16 a...

Page 8: ...y The UPS has a dual inverter design capable of providing simultaneous output voltages of 240 120 208 120 230 115 220 110 or 200 100 The new 6U cabinet is the smallest for 208 120 selectable voltage in the 10 kVA size The unit features integrated internal manual and automatic maintenance bypass swappable power module battery modules auto detection of extended battery cabinets and optional plug and...

Page 9: ... A single part number installs in either configuration Automatic frequency detection The Liebert GXT2 10 kVA detects and matches line input frequencies of either 60 or 50 Hz Additional runtime with 4U battery cabinets UPS cabinet includes rear panel plug n play connections for optional additional battery cabinets Use up to three cabinets for extended battery runtime applications Contact Liebert Te...

Page 10: ...2 Output 4 5 20R T type 4 L6 30R The Parallel POD will require start up purchase for each GXT2 10000RT208 connected to the system Parallel Communication Ports Electronic equipment may be installed at the front of the rack with the Parallel POD installed at the back of the rack increasing usable space Equipment shown from back of rack Input Output Power For Paralleled UPS Units Increase The Flexibi...

Page 11: ... for hardwired connections for the input and output Optional additional battery charger for 230V tower model where long runtime and fast recharge are required Liebert GXT2 10 kVA 230V Liebert GXT2 10 kVA 230 240V Tower A tower configuration is also available in a 230V version and a 220V version with voltage transformer The standard 10 kVA model includes terminal blocks for hardwired connections of...

Page 12: ...f external battery cabinets connected allowing the UPS to report the correct run time Communications For Power Monitoring And Control The Liebert GXT2 6 kVA and 10 kVA systems offer a variety of communications options to provide the monitoring and control capabilities demanded by today s network computing systems Operation can be monitored using Liebert MultiLink Automated System Shutdown Software...

Page 13: ...system start up by a certified Service Division of Emerson Network Power Customer Engineer scheduled anytime 24 x 7 This includes removal and disposal of your existing UPS Preventive Maintenance One preventive maintenance visit completed in year 3 by a certified Emerson Network Power Customer Service Engineer includes 100 Parts Coverage even internal batteries Full Parts Coverage Your on line Lieb...

Page 14: ... shutdown 130 for 60 seconds with transfer to bypass with transfer to bypass ENVIRONMENTAL Operating Temp 32 F to 104 F 0 C to 40 C Storage Temp 5 F to 122 F 15 C to 50 C Relative Humidity 0 to 95 non condensing Operating Elevation Up to 10 000 ft 3000m at 104 F 40 C without derating Storage Elevation 50 000 ft 15 000 m maximum Audible Noise 55 dBA at 1 meter from the rear 50 dBA at 1 meter from t...

Page 15: ... VDC 14 min 25 min GXT2 6000RT230 7 min GXT2 240VBATT 240 VDC 21 min 38 min GXT2 4500RT230 10 min GXT2 240VBATT 240 VDC 31 min 54 min GXT2 10000RT208 5 min GXT2 288RTVBATT 288 VDC 14 min 25 min GXT2 10000R230 NA GXT2 240RVBATT 240 VDC 5 min 15 min GXT2 10000T230 5 min GXT2 240TBATTCE 240 VDC 23 min 43 min GXT2 10000T220 5 min GXT2 240TBATTUL 240 VDC 22 min 42 min INTERNATIONAL MODELS Model Input V...

Page 16: ...n Network Power logo are trademarks and service marks of Emerson Electric Co 2008 Emerson Electric Co While every precaution has been taken to ensure accuracy and completeness in this literature Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 2008 Liebert Corporation All rights reserved thro...

Reviews: