background image

6

OPERATING YOUR THERMOSTAT

Choose the Fan Setting (Auto or On)

Set the FAN Switch to 

Auto

 or 

On

.

Fan 

Auto

 is the most commonly selected setting and runs the 

fan only when the heating or cooling system is on.
Fan 

On

 runs the fan continuously for increased air circulation 

or to allow additional air cleaning.

Choose the System Setting
(Heat, Off, Cool, Auto)

Press the SYSTEM button to select:

Heat: 

Thermostat controls only the heating system.

Off:

 Heating and Cooling systems are off.

Cool:

 Thermostat controls only the cooling system.

Auto:

 Auto Changeover is used in areas where both heating 

and cooling may be required on the same day. 

AUTO

 allows 

the thermostat to automatically select heating or cooling 
depending on the indoor temperature and the selected heat 
and cool temperatures. When using 

AUTO

, be sure to set the 

Cooling temperatures more than 1° Fahrenheit higher than 
the heating temperature.

Manual Operation for Non-Programmable 
Thermostats Mode

Press the SYSTEM button to select Heat or Cool and use
the 

 or 

 buttons to adjust the temperature to your

desired setting. After selecting your desired settings you can
also press the SYSTEM button to select 

AUTO

 to allow

the thermostat to automatically change between Heat and
Cool.

Set Current Time and Day

1)  Press Menu and then Time button once. The display
 

will show the hour only.

2)  Press and hold either the 

 or 

 button until you  

 

reach the correct hour and AM/PM designation (AM be- 

 

gins at midnight, PM begins at noon).

3)  Press Time once again. The display window will show
 

the minutes only.

4)  Press and hold either the 

 or 

 button until you  

 

reach the correct minutes.

5)  Press Time once again. The display will show the day
 

of the week.

6) Press the 

 or 

 button until you reach the current  

 

day of the week.

7)  Press Run to exit the Time mode.

Enter the Heating Program

1)  Press SYSTEM button to select 

"Heat"

 in the system 

 

switch area indicating the active mode being pro-

 grammed.
2)  Press the Menu button and then press Schedule. 
3)  The top of the display will show the day(s) being pro-
 

grammed. The time and temperature (fl ashing) are also

 displayed. 

"1"

 will also be displayed to indicate the period.

4) Press 

 or 

 button to change the temperature to  

 

your selected temperature for the 1st heating period.

5)  Press Time button, time will fl ash.
6) Press 

 or 

 button to adjust the start time for the

 1st 

period.

7)  The time will change in 15 minute increments.
8)  After you have set the time and the temperature for 
 

the period to begin, press Schedule to advance to the

 

next program period.

9)  Repeat steps 2 through 8 until all of the program times
 

and temperatures are set for all program periods on 

 that 

day. 

10) Press Schedule to the next day and repeat steps 2 
 through 

9.

11) When programming is complete and all of the times and 
 

temperatures match your desired heating schedule, press 

 

Run Schedule. The thermostat will now run your program.

Enter the Cooling Program

1)  Press SYSTEM button to select 

"Cool"

 in the system 

 

switch area indicating the active mode being pro-

 grammed.
2) Follow 

Enter Heating Program

 instructions for entering

 

cooling times and temperatures.

PROGRAMMING (For Programmable Model Only) 

IMPORTANT!

Manual Operation (Bypassing the Program)
Programmable Thermostats

Press 

 or 

 and the HOLD button and adjust the tem-

perature wherever you like. This will override the program. 
The 

HOLD

 feature bypasses the program and allows you 

to adjust the temperature manually, as needed. Whatever 
temperature you set in 

HOLD

 will be maintained 24 hours 

a day, until you manually change the temperature or press 

Run Schedule

 to cancel 

HOLD

 and resume the programmed 

schedule.

Program Override (Temporary Override)

Press 

 or 

 buttons to adjust the temperature. This will 

override the temperature setting until the next programmed 
time. To cancel the temporary setting at any time and return 
to the program, press 

Run Schedule

. If the SYSTEM button 

is pressed to select 

AUTO

 the thermostat will change to Heat 

or Cool, whichever ran last. If it switches to heat but you want 
cool, or it changes to cool but you want heat, press both 

 

and 

 buttons simultaneously to change to the other mode.

Summary of Contents for 1F80-0471

Page 1: ...ntial Single Stage Heat 0 6 F Cool 1 2 F adjustable Differential Heat Pump Heat 1 2 F Cool 1 2 F adjustable Operating Ambient 32 to 105 F 0 to 41 C Operating Humidity 90 non condensing max Shipping Temperature Range 4 to 150 F 20 to 65 C Dimensions Thermostat 3 4 H x 4 4 W x 1 3 D Topreventelectricalshockand orequipmentdamage disconnect electric power to system at main fuse or circuit breaker box ...

Page 2: ...ing a call for heat If your heat is gas or oil the switch should be set to the GAS position When the thermostat is configured for Heat Pump the thermo stat will always power the circulator fan on a call for heat in the HEAT mode 2 Batteries 2 AA alkaline batteries are included in the thermostat To in stall the batteries pull the battery door as shown by the arrow and lift open Using the polarity i...

Page 3: ...Mode 7 Displays Run Schedule Schedule or Menu 8 Displays Save when Cool SavingsTM is working 9 Displays Heat Pump when system is configured as Heat Pump thermostat 10 Displays Hold in programmable mode when in Hold mode Displays Light Bulb in non program mable mode 1 Flame icon is displayed when the system is in HEAT mode Snowflake icon is displayed when the system is in COOL mode 2 The word Hold ...

Page 4: ...he displayed temperature to a maximum number of degrees selected Adjusting the setpoint temperature over a long cooling run time allows the system to reach your set temperature and turn off The room temperature will actually be higher than the thermostat displays but the reduction in humidity will allow comfort at the slightly higher temperature When Cool Savings is making adjustments Save will sh...

Page 5: ...ash the setpoint for up to five minutes 9 System Mode Configuration This thermostat is configured for Heat and Cool withAuto changeover SYSTEM switch with Cool Off Heat Auto default It can also be configured for Heat and Cool Cool Off Heat Heat only with fan Off Heat Heat only without fan Auto only Auto Off and Cool only Cool Off 10 Select Backlight Display The display backlight improves display c...

Page 6: ...d then press Schedule 3 The top of the display will show the day s being pro grammed The time and temperature flashing are also displayed 1 will also be displayed to indicate the period 4 Press or button to change the temperature to your selected temperature for the 1st heating period 5 Press Time button time will flash 6 Press or button to adjust the start time for the 1st period 7 The time will ...

Page 7: ...ing guidelines in mind when planning your program In Heating lower temperatures will save energy In Cooling higher temperatures will save energy If you plan on using Auto Changeover do not program the heating higher than the cooling Worksheet for Re Programming 5 2 Day and 5 1 1 Day Program PROGRAMMING For Programmable Model Only Wake Up Period 1 Leave For Work Period 2 Return Home Period 3 Go To ...

Page 8: ...k Try resetting the thermostat as described above If the condition persists the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system oper ates correctly replace the thermostat Thermostat Setting Thermostat Thermometer Disagree 1 Thermostat thermometer setting requires adjustment The thermometer can be adjusted 4 degr...

Page 9: ... 6 F frío 1 2 F ajustable Diferencial bomba de calor Calor 1 2 F frío 1 2 F ajustable Temperatura ambiente operativa 32 F a 105 F 0 C a 41 C Humedad operativa 90 sin condensación máx Rango de temperatura de transporte 4 F a 150 F 20 C a 65 C Dimensiones del termostato 3 4 pulg Al x 4 4 pulg An x 1 3 pulg P Paraevitardescargaseléctricasy odañosalequipo desconecte la alimentación eléctrica en la caj...

Page 10: ...rruptor debe ajustarse en la posición GAS Cuando está configurado para bomba de calor el termostato siempre activa el ventilador circulador en una llamada de calor en el modo HEAT pilas alcalinas AA Figura 1 Puerta del compartimiento de las pilas abierta Orificio de montaje Orificio de montaje Colocar nivelado a través de las lengüetas de montaje sólo por razones estéticas SS HP GAS ELEC Interrupt...

Page 11: ...ule programa o Menu menú 8 Muestra Save ahorro cuando Cool SavingsTM está en funcionamiento 9 Muestra Heat Pump bomba de calor cuando el sistema está configurado como termostato de bomba de calor 10 Muestra Hold mantener en el modo programable cuando está en el modo Hold Muestra Light Bulb bombilla en el modo no programable 1 El icono de la llama aparece cuando el sistema está en el modo HEAT El i...

Page 12: ...viene ajustada de fábrica en la posición O Esta posición admite la mayoría de las aplicaciones de bomba de calor que requieren que el relé de conmutación esté energizado en COOL Si el termostato que está cambiando o la bomba de calor en la que está instalando este termostato requiere una terminal B para energizar el relé de conmutación en HEAT el interruptor O B debe colocarse en la posición B 2 O...

Page 13: ...r del termostato la pantalla mostrará la temperatura de referencia de forma intermitente durante un máximo de cinco minutos 9 Configuración del modo del sistema Este termostato está configurado para calor y frío con opción predeterminada de conmutación automática interruptor SYSTEM con Cool Off Heat Auto También puede configurarse para calor y frío Cool Off Heat sólo calor con ventilador Off Heat ...

Page 14: ...AUTO el termostato cambiará a Heat o Cool según cuál fue el último que se ejecutó Si cambia a calor pero usted desea frío o si cambia a frío pero usted desea calor presione los botones o simultáneamente para pasar al otro modo Ajuste la hora y día actuales 1 Presione Menu y luego el botón Time una sola vez La pantalla mostrará la hora únicamente 2 Presione y mantenga presionado los botones o hasta...

Page 15: ...n programa de 5 2 días ingrese sus propias horas y temperaturas directamente a continuación debajo de las horas y temperaturas de fábrica Si desea reprogramar con un programa de 5 1 1 días complete todas las líneas con las horas y temperaturas que desea Tenga en cuenta las siguientes indicaciones cuando planifique su programa En calefacción las temperaturas más bajas ahorran energía En enfriamient...

Page 16: ...N Verifique todas las conexiones de los cables para asegurarse de que no estén en cortocircuito o tocándose entre sí No debe sobresalir ningún cable pelado por debajo del bloque de terminales Intente reajustar el termostato como se describe más arriba Si la condición persiste el fabricante de su sistema o el personal técnico podrá indicarle cómo probar si el sistema de frío calor está funcionando ...

Reviews: