background image

11

Repair Parts Listing

Part Numbers

Key

Model No.

Model No.

No. Description

ACF552ORB00

ACF552WW00

*

Hanger Ball Assembly,

761655-32

761655

Consisting of:

1

Hanger Bracket

2

Hanger Ball

3

Downrod

*

Parts Bag Containing:

763913-BLOXSS 763913-SS

4

Pin, Clevis (1)

5

Clip, Hairpin (1)

6

Stud, Threaded, #8-32 x 1-1/4” (2)

7

Lockwasher, External Tooth, #8 (2)

8

Nut, Knurled, #8-32 (2)

9

Screw, Serrated Pan Head,

M4 x 10mm (1)

10

Screw, Flat Head, M4 x 12mm (1)

11

Screw, Washer Head Blade (16)

12

Screw, M6 x 14mm Pan Head

with Lockwasher (1)

13

Balancing Kit (1)

14

Pad, Canopy Seal

764376

764376

15

Cover, Ceiling

763921-ORB

763921-WW

16

Cover, Coupling

764054-ORB

764054-WW

17

Harness, Wiring

764375-BLK

764375-WW

18

Switch Cup Cover

763915-ORB

763915-WW

19

Switch Cup 

763919-ORB

763919-WW

20

Fan Blades (set of 5)

763910-ORB

763910-WW

21

Blade Flanges (set of 5)

763908-ORB

763908-WW

Owner's Manual

BP7461

BP7461

Before discarding packaging material, be certain all parts have been removed.

HOW TO ORDER REPAIR PARTS

WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:

• PART NUMBER

• NAME OF ITEM

• PART DESCRIPTION

• MODEL NUMBER

The model number of your Fan will be found on a label attached to the top housing.

For repair parts:

Model No.: ACF552

Ceiling  fan  performance  and  energy  savings
rely heavily on the proper installation and use
of the ceiling fan. Here are a few tips to ensure
quality and product performance.

Choosing  the  Appropriate  Mounting
Location. 

Ceiling fans should be installed, or

mounted,  in  the  middle  of  the  room  and  at
least 2.1 m above the floor and 50 cm from the
walls.  If  ceiling  height  allows,  install  the  fan
2.4m - 2.7m above the floor for optimal airflow. 

Using  the  Ceiling  Fan  Year  Round.

In  the

summer,  use  the  ceiling  fan  in  the  counter-
clockwise  direction.  The  airflow  produced  by
the  ceiling  fan  creates  a  wind-chill  effect,
making  you  "feel"  cooler.  Select  a  fan  speed
that  provides  a  comfortable  breeze,  lower
speeds  consume  less  energy.  In  the  winter,
reverse  the  motor  and  operate  the  ceiling  fan
at  low  speed  in  the  clockwise  direction.  This
produces a gentle updraft, which forces warm
air  near  the  ceiling  down  into  the  occupied
space.  Remember  to  adjust  your  AIRCON
thermostat  when  using  your  ceiling  fan  -
additional  energy  and  dollar  savings  could  be
realized with this simple step! 

Turn  Off  When  Not  in  the  Room. 

Ceiling

fans  cool  people,  not  rooms.  If  the  room  is
unoccupied,  turn  off  the  ceiling  fan  to  save
energy.

Energy Efficient Use of

Ceiling Fans

Phone: 1300 469 326

info@myfan.com.au

www.myfan.com.au

Summary of Contents for ACF552ORB00

Page 1: ...LECTRICIAN The warranty on this fan will be void if the appliance is not installed by a licensed electrician This ceiling fan is imported by MyFan as an agent for the USA design owners and can provide after sales service for this product if required Contact can be made by phone fax or email during normal trading hours Copies of owner s manuals for each model can be found on our web site Phone 1300...

Page 2: ...nished with the fan provides the minimum recommended floor to fan blade clearance for a 2 4 m ceiling 5 The fan must be mounted with the fan blades at least 2 1 meters from the floor to prevent accidental contact with the fan blades 6 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless ...

Page 3: ... stripper The fan must be installed by a licensed electrician WARNING THIS FAN IS SUITABLE FOR WET LOCATIONS SUCH AS PORCHES PATIOS AND DECKS USE ONLY WITH LIGHT KITS MARKED SUITABLE FOR USE IN WET LOCATIONS Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been com...

Page 4: ...ve or fan wobble could result PIN HANGER BALL SETSCREW DOWNROD Figure 1 SETSCREW CLEVIS PIN DOWNROD HAIRPIN CLIP MOTOR COUPLING SETSCREW CLEVIS PIN HAIR PIN CLIP CLEVIS PIN STRAIGHT LEG OF CLEVIS PIN MOTOR COUPLING Figure 2 DOWNROD COUPLING COVER GROMMET CEILING COVER Figure 3 It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failur...

Page 5: ...n the third hole in the cover with vacant threaded hole on the lower housing adapter Re install the screw removed in Step 13 into the aligned holes Securely tighten all three screws figure 8 NOTE Make sure wires are not pinched between switch cup cover and lower housing adapter BLADE ASSEMBLY M6 x 14mm CAPTIVE SCREW WITH LOCKWASER REMOVE ONE M4 x 10mm SERRATED PAN HEAD SCREW LOWER HOUSING ADAPTER ...

Page 6: ... fuse box at this time and remove the existing light fixture The hanger bracket must be securely anchored and capable of withstanding a load of at least 40kg Figure 11 depicts typical structural configuration that may be used for securely mounting the fan Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wirin...

Page 7: ...ast 2 1 meters of clearance from floor to blades Figure 12 WARNING The hanger bracket must be securely mounted to the ceiling joist and capable of supporting at least 40 Kg WARNING How To Hang This Ceiling Fan MAIN FUSE BOX Figure 15 NOTE CEILING COVER AND FAN WIRES OMITTED FOR CLARITY 1 Turn off the branch circuit electricity at the main fuse box Figure 15 2 Plug the hanger ball green yellow grou...

Page 8: ...e ceiling cover 3 Secure the ceiling cover in place by sliding the 8 lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 17 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling Your fan is now wired to be turned on and off from the wall switch 7 Securely connect the branch circuit supply cable green yellow earth wire to the...

Page 9: ... 5 Screws holding blades to blade flanges 5 Tighten screws securely are loose 3 Fan wobbles 1 Setscrews in motor coupling are loose 1 Tighten both setscrews securely in the motor excessively coupling 2 Setscrew in hanger ball downrod 2 Tighten the setscrew in the hanger ball assembly is loose downrod assembly 3 Screws securing fan blade flanges to 3 Check to be sure screws which attach the fan mot...

Page 10: ...w ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING ...

Page 11: ...ttached to the top housing For repair parts Model No ACF552 Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 2 1 m above the floor and 50 cm from the w...

Page 12: ...btain any after sales service Keep your tax invoice or other proof of purchase together with the installing electrician s details Do not uninstall or attempt to return the product to the supplier or MyFan unless advised to by MyFan You must be the original purchaser of the product and it must be installed in its original point of installation to be covered by this warranty Warranty periods begin f...

Reviews: