Specifications

Power Supply Specifications

ALP-130 Dimensions 

Model

Input

Output

IP

Rated 

Ambient 

Temperature

Weight

ALP-130

115/230 VAC

40 Watts

140 VDC

30 Watts

20

50° C (122° F)

1.6 lbs

(.07 kg)

ALP-430

115/230 VAC

130 Watts

140 VDC

(4) x 20 Watts

20

50° C (122° F)

7.7 lbs

(3.5 kg)

0.25

0.25

2.0 min.

2.0 min.

A

L

P

-1

3

0

 a

n

d

 A

L

P

-4

3

0

Summary of Contents for ALP-130

Page 1: ...gn or operation of the equipment described herein and any associated motion products without notice EMERSON Motion Control also assumes no responsibility for any errors that may appear in this document Information in this document is subject to change without notice P N 400514 01 Rev A2 Date October 22 1999 1999 EMERSON Motion Control All rights reserved ALP 130 and ALP 430 Auxiliary Logic Power S...

Page 2: ...red trademarks of Microsoft Corporation IBM is a registered trademark of International Business Machines Inc Modbus is a trademark of Modicon Inc Data Highway Plus is a trademark of Allen Bradley Schaffner is a trademark of Schaffner Commercial names of products from other manufacturers or developers that appear in this manual are registered or unregistered trademarks of those respective manufactu...

Page 3: ...tion Control support information 24 hours a day seven days a week Our wide range of services include FAX 612 995 8011 You can FAX questions and comments to EMERSON Motion Control Just send a FAX to the number listed above Website and Email www emersonmotioncontrol com Website www emersonmotioncontrol com Email info emersonmotioncontrol com If you have Internet capabilities you also have access to ...

Page 4: ...able through our service organization When you call please be at your computer have your documentation in hand and be prepared to provide the following information Product version number found by choosing About from the Help menu The type of controller or product you are using Exact wording of any messages that appear on your screen What you were doing when the problem occurred How you tried to so...

Page 5: ...995 8000 Email sales emersonmotioncontrol com Authorized EMERSON Motion Control distributors may place orders directly with our Order Processing Department by calling the number listed above For information on your local distributor call EMERSON Motion Control Document Conventions Manual conventions have been established to help you learn to use this manual quickly and easily As much as possible t...

Page 6: ...manual and product a qualified person is one who is familiar with the installation construction and operation of the equipment and the hazards This Represents bold Characters that you must type exactly as they appear For example if you are directed to type a setup you should type all the bold characters exactly as they are printed italic Place holders for information you must provide For example i...

Page 7: ...is manual and product Warning indicates death severe personal injury or substantial damage CAN result if proper precautions are not taken Caution For the purpose of this manual and product Caution indicates minor personal injury or property damage CAN result if proper precautions are not taken Note For the purpose of this manual and product Note indicates information about the product or the respe...

Page 8: ...Power Supply Installation Manual E Series Only EN For the purpose of this manual and product the EN symbol indicates information about the E Series drive specifically Throughout this manual the word drive refers to an Epsilon or E Series drive ...

Page 9: ...itions of acceptability required by UL are The ALP 130 ambient temperature must be 40 C 104 F or less The ALP 430 ambient temperature must be 50 C 122 F or less CE Declaration of Conformity The ALP 130 430 Auxiliary Logic Supply is marked with the Conformite Europeenne Mark CE mark after passing a rigorous set of design and testing criteria This label indicates that this product meets safety stand...

Page 10: ... not apply Supplementary information This electronic drive product is intended to be used with an appropriate motor electrical protection components and other equipment to form a complete end product or system It must only be installed by a professional assembler who is familiar with requirements for safety and electromagnetic compatibility EMC The assembler is responsible for ensuring that the en...

Page 11: ...N 61000 4 8 30 A m ENV 50141 1993 80 AM 10V 15 80 MHz ENV 50204 1995 Pulse 900 MHz 50 DTY 200 Hz Supplementary information The products herewith comply with the requirements of the Low Voltage Directive LVD 73 23 EEC and EMC Directive 89 336 EEC This electronic drive product is intended to be used with an appropriate motor electrical protection components and other equipment to form a complete end...

Page 12: ......

Page 13: ...0 1 Installation ALP 130 Wiring Example 3 ALP 430 Wiring Example 4 Installation Procedure 5 ALPC xxx Cable Installation Instructions 7 Specifications Power Supply Specifications 9 ALP 130 Dimensions 9 ALP 430 Dimensions 10 Table of Contents ALP 130 and ALP 430 ...

Page 14: ......

Page 15: ...e on the drive Note The ALP 130 is considered a Class 2 device As such there is not a connection for PE on the ALP 130 Protect Class 2 referes to any equipment in which protection against electrical shock does not rely on basic insulation only but in which additonal safety precautions such as double insulation or reinforced insulation are provided there being no provision for protective earthing o...

Page 16: ...st mounting tracks or enclosures and includes the screw terminal plug connectors to mate with the auxiliary supply receptacle on the drives and the drive end connector kit and includes four 4 ALPC xxx cables to mate with the recepticle on the drive ...

Page 17: ...3 Installation ALP 130 Wiring Example 230 VAC Backup Power ALPC xxx Cable ALP 130 and ALP 430 ...

Page 18: ...4 ALP 130 and ALP 430 Installation Manual ALP 430 Wiring Example 230 VAC Backup Power ALPC xxx Cable ...

Page 19: ...LP 130 430 installation and fusing Use 16 to 18 AWG 600V insulated stranded wire for AC in and DC out wiring The ALP 130 and ALP 430 package includes the cable assembly that mates with the 2 position header s on your drive s Figure 1 ALP 130 Connections and Internal Wiring Diagram ...

Page 20: ...6 ALP 130 and ALP 430 Installation Manual Figure 2 ALP 430 Connections and Internal Wiring Diagram ...

Page 21: ...must be used in order to maintain the UL Listing on the drives and on the ALP 130 430 power supplies Note Refer to the ALP 130 and ALP 430 Auxiliary Power Supply Installation Manual P N 400514 01 for power supply installation instructions 1 Break out the plastic knock out tab in the J3 location on the top of the drive 2 Plug the connector end of the ALPC xxx cable into the two position receptacle ...

Page 22: ... higher use a spring terminal for J3 rather than a header These drives will not use the ALPC xxx cable See drawing below for connection descriptions for this type of drive Figure 2 Signal Description with the Original Design Spring Terminal in the J3 Location Two position receptacle The mating connector cable assembly ALPC xxx plugs into the receptacle Additional cables available from EMERSON Moti...

Page 23: ...sions Model Input Output IP Rated Ambient Temperature Weight ALP 130 115 230 VAC 40 Watts 140 VDC 30 Watts 20 50 C 122 F 1 6 lbs 07 kg ALP 430 115 230 VAC 130 Watts 140 VDC 4 x 20 Watts 20 50 C 122 F 7 7 lbs 3 5 kg 0 25 0 25 2 0 min 2 0 min ALP 130 and ALP 430 ...

Page 24: ...10 ALP 130 and ALP 430 Installation Manual ALP 430 Dimensions 6 53 0 18 2 25 7 05 7 50 0 23 2 95 0 35 0 22 2 0 min 2 0 min 0 25 0 25 ...

Reviews: