Supported IPMI Commands
ATCA-7368 Installation and Use (6806800M12C
)
116
7.4.2
Serial Output Commands
7.4.2.1
Set Serial Output Command
The Set Serial Output command selects the serial port output source for a serial port
connector.
7.4.2.1.1 Request Data
The following table lists the request data applicable to the Set Serial Output command.
Table 7-23 Feature Selector Assignments
Feature Selector
Description
E2h
Boot Firmware Automatic Switchover Function Enable/Disable
Table 7-24 Serial Output Commands
Command Name
NetFn (Request/Response)
CMD
Description
Set Serial Output
0x2E/0x2F
0x15
Get Serial Output
0x2E/0x2F
0x16
Table 7-25 Request Data of Set Serial Output Command
Byte
Data Field
1
LSB of Emerson IANA Enterprise number. A value of 0xCD has to be used.
2
Second byte of Emerson IANA Enterprise number. A value of 0x65 has to be used.
3
MSB of Emerson IANA Enterprise number. A value of 0x00 has to be used.