Supported IPMI Commands
ATCA-7368 Installation and Use (6806800M12C
)
126
7.5.5
Set Debug Level Command
The Set Debug Level command sets the current debug level of the IPMC firmware.
Table 7-35 Set Debug Level Command Description
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
4
Bit [7] IPMB-L Dump Enable
If set to "1", the IPMC provides a trace of IPMB-L messages
that are arriving to/going from the IPMC via IPMB-L.
Bit [6] n/a
Bit [5] KCS Dump Enable
If set to "1", the IPMC provides a trace of KCS messages
that are arriving to/going from the IPMC via KCS.
Bit [4] IPMB Dump Enable
If set to "1", the IPMC provides a trace of IPMB messages
that are arriving to/going from the IPMC via IPMB-O.
Bit [3] n/a
Bit [2] Alert Logging Enable
If set to "1", the IPMC outputs important alert messages
onto the serial debug interface.
Bit [1] Low-level Error Logging Enable
If set to "1", the IPMC outputs low-level error/diagnostic
messages onto the serial debug interface.
Bit [0] Error Logging Enable
If set to "1", the IPMC outputs error/diagnostic messages
onto the serial debug interface.
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00
Summary of Contents for ATCA-7368
Page 8: ...ATCA 7368 Installation and Use 6806800M12C Contents 8 Contents Contents ...
Page 14: ...ATCA 7368 Installation and Use 6806800M12C 14 List of Figures ...
Page 50: ...Hardware Preparation and Installation ATCA 7368 Installation and Use 6806800M12C 50 ...
Page 88: ...Functional Description ATCA 7368 Installation and Use 6806800M12C 88 ...
Page 210: ...Replacing the Battery ATCA 7368 Installation and Use 6806800M12C 210 ...
Page 221: ......