FRU Information and SDR Summary
ATCA-7368 Installation and Use (6806800M12C)
181
Event/Reading Type
0x01
Threshold
Assertion Event Mask
(Byte 15)
0x14 -
Assertion Event Mask
(Byte 16)
0x6A -
Deassertion Event Mask
(Byte 17)
0x14 -
Deassertion Event Mask
(Byte 18)
0x6A -
Threshold Mask (Byte 19) 0x36
-
Threshold Mask (Byte 20) 0x36
-
Base Unit
0x04
Volts
Rearm mode
0x01
Auto
Hysteresis Support
0x02
Readable and settable
Threshold Access
Support
0x02
Readable and settable
Event Message Control
0x00
Per Threshold/Discrete
State
Nominal Reading
0x7B
1.2
Upper non-recoverable
threshold
0x88 1.4
Upper critical threshold
0x82
1.3
Upper non-critical
threshold
0x00 (unspecified)
Lower non-recoverable
threshold
0x6E 1.1
Lower critical threshold
0x74
1.0
Lower non-critical
threshold
0x00 (unspecified)
Reading Definition
Analog reading byte
Analog sensor reading
Table 8-29 1.2V (continued)
Feature
Raw Value
Description
Summary of Contents for ATCA-7368
Page 8: ...ATCA 7368 Installation and Use 6806800M12C Contents 8 Contents Contents ...
Page 14: ...ATCA 7368 Installation and Use 6806800M12C 14 List of Figures ...
Page 50: ...Hardware Preparation and Installation ATCA 7368 Installation and Use 6806800M12C 50 ...
Page 88: ...Functional Description ATCA 7368 Installation and Use 6806800M12C 88 ...
Page 210: ...Replacing the Battery ATCA 7368 Installation and Use 6806800M12C 210 ...
Page 221: ......