FRU Information and SDR Summary
ATCA-7368 Installation and Use (6806800M12C)
179
Upper non-critical
threshold
0x00 (unspecified)
Lower non-recoverable
threshold
0xA4 1.7
Lower critical threshold
0xAD
1.6
Lower non-critical
threshold
0x00 (unspecified)
Reading Definition
Analog reading byte
Analog sensor reading
Table 8-28 1.5V
Feature
Raw Value
Description
Sensor Name
1.5V
-
Sensor LUN
0x00
-
Sensor Number
0x17
-
Entity ID
0x14
power module / DC-to-DC
converter
Sensor Type
0x02
Voltage
Event/Reading Type
0x01
Threshold
Assertion Event Mask
(Byte 15)
0x14 -
Assertion Event Mask
(Byte 16)
0x6A -
Deassertion Event Mask
(Byte 17)
0x14 -
Deassertion Event Mask
(Byte 18)
0x6A -
Threshold Mask (Byte 19) 0x36
-
Threshold Mask (Byte 20) 0x36
-
Table 8-27 1.8V Eth (continued)
Feature Raw
Value
Description