Supported IPMI Commands
ATCA-7368 Installation and Use (6806800M12C
)
98
7.2.5
FRU Inventory Commands
7.2.6
Sensor Device Commands
Table 7-5 Supported FRU Inventory Commands
Command
NetFn (Request/Response)
CMD
Get FRU Inventory Area Info
0x0A/0x0B
0x10
Read FRU Data
0x0A/0x0B
0x11
Write FRU Data
0x0A/0x0B
0x12
Table 7-6 Supported Sensor Device Commands
Command
NetFn
(Request/Response) CMD
Comments
Get Device SDR Info
0x04/0x05
0x20
-
Get Device SDR
0x04/0x05
0x21
-
Reserve Device SDR Repository
0x04/0x05
0x22
-
Get Sensor Reading Factors
0x04/0x05
0x23
-
Set Sensor Hysteresis
0x04/0x05
0x24
-
Get Sensor Hysteresis
0x04/0x05
0x25
-
Set Sensor Threshold
0x04/0x05
0x26
Most of the threshold-based
sensors have fixed thresholds.
Before using this command,
check whether threshold
setting is supported by using
the Get Device SDR command.
Get Sensor Threshold
0x04/0x05
0x27
-
Set Sensor Event Enable
0x04/0x05
0x28
-
Get Sensor Event Enable
0x04/0x05
0x29
-
Get Sensor Event Status
0x04/0x05
0x2B
-
Summary of Contents for ATCA-7368
Page 8: ...ATCA 7368 Installation and Use 6806800M12C Contents 8 Contents Contents ...
Page 14: ...ATCA 7368 Installation and Use 6806800M12C 14 List of Figures ...
Page 50: ...Hardware Preparation and Installation ATCA 7368 Installation and Use 6806800M12C 50 ...
Page 88: ...Functional Description ATCA 7368 Installation and Use 6806800M12C 88 ...
Page 210: ...Replacing the Battery ATCA 7368 Installation and Use 6806800M12C 210 ...
Page 221: ......