7
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: CF810
AT LEAST
7'
CEILING
FLOOR
Figure 10
TWO SCREWS
SUPPLIED WITH
OUTLET BOX
HANGER
BRACKET
TAB
OUTLET
BOX
Figure 11
OUTLET
BOX
HANGER
BRACKET
HANGER BALL/
DOWNROD
ASSEMBLY
NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES OMITTED
FOR CLARITY.
Figure 12
How to Hang Your Ceiling Fan
The outlet box and joist must be securely mounted and
capable of supporting at least 50 lbs. Use only a U.L.
outlet box listed as “Acceptable for Fan Support of
15.9kg. (35 lbs.) or less”.
WARNING
!
Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.
WARNING
!
To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable for
Fan Support of 15.9kg. (35 lbs.) or less”, and use
screws supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are not
acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.
WARNING
!
The fan must be hung with at least 7' of clearance from
floor to blades (Figure 10).
WARNING
!
1.
Securely attach the hanger bracket to the outlet box
using the two screws supplied with the outlet box.
(Figure 11.)
2.
Carefully lift the fan and seat the hanger ball/
downrod assembly on the hanger bracket that was
just attached to the outlet box (Figure 12). Be sure
the groove in the ball is lined up with tab on the
hanger bracket (Figure 11).
Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.
WARNING
!