Operator
Control Panel Cover
Mounting
Arrangement
“A”
Flange Adaptor for Matching Valve
(Shipped bolted to operator)
Valve KEY, __ X __ X__ LG, QTY __
Valve Gear Flange
Valve BOLTS, _____ X __ LG, QTY __
Spool type adaptor for matching valve
(shipped bolted to operator or loose
depending on crating restrictions)
Valve STUDS W/NUTS, _____ X __ LG, QTY __
Operator KEY, __ X __ X __ LG, QTY __
Valve Stem Connector to Operator
Valve key retained in stem connector
Valve Gear Flange
Valve BOLTS, _____ X __ LG, QTY __
Operator BOLTS, _____ X __ LG, QTY __
Valve STUDS, _____ X __ LG, QTY __
C/W NUTS, QTY __
Mounting
Arrangement
“B”
Tolerances
XXX ±
0.5 [±10]
XX ±
0.2 [±5]
X ±
0.1 [±2]
November 2021
Installation, Operation and Maintenance Manual
DOC.IOM.RG.US Rev. 11
4
Section 2: Operating Instructions
Operating Instructions
Figure 2
Mounting instructions for valves with gear flanges
Operator
Control Panel Cover
Flange Adaptor for Matching Valve
(Shipped bolted to operator)
Valve KEY, _X_X_LG, QTY__
Valve Gear Flange
Valve STUDS W/NUTS,___X_LG, QTY__
Valve BOLTS,___X_LG, QTY__
Spool Type Adaptor for Matching Valve
(shipped bolted to operator o r loose
depending on crating restrictions)
Operator BOLTS,___X_LG, QTY__
Operator KEY, _X_X_LG, QTY__
Valve Stem Connector to Operator
Valve key retained in stem connector
Valve Gear Flange
Valve BOLTS,___X_LG, QTY__
Valve STUDS,___X_LG, QTY__
C/W NUTS, QTY__
Mounting
Arrangement
"B"
Mounting
Arrangement
"A"
NOTE:
Operator is typically shipped in OPEN position. Mounting hardware is located on a pallet or inside the
control panel cover.