Section 7: Maintenance
Maintenance
B.
For SR Type Operator:
Since spring load is not acting against the end stop (32), remove end stop cover (33)
directly and mark the end stop (32) engaged position to facilitate reassembly.
4.
Mark the port and tubing locations to facilitate reassembly. Disconnect
tubing if required (but can leave the fitting on the operator components to
ease reassembly).
5.
Loosen setscrew (97), (98), and (99) in swivel connector (80). Unthread the
stem nut from the valve stem to disengage valve stem from operator connector
(if removal of the operator from the valve is required). Free the operator from valve
by removing the mounting bolt. Then, unthread the connector assembly (80) from
the drive rod (1). This will allow the drive rod (1) and piston (11) to be removed
completely from the operator.
6.
Remove stay rod nuts (91), lift lugs (35), end cap (8), upper cylinder seal (55).
!
CAUTION
Do not remove stay rod nuts (91) completely from stay rod (22) until spring load is cleared.
Allowing the end cap to move up slightly will release the spring preload inside the operator.
Loosening stay rod nuts (91) in pairs (with one across the other) will prevent sudden
movement of the end cap (8).
7.
Remove only enough stay rods (22) to allow access for the removal of cylinder (17)
and piston (11).
8.
Remove cylinder (17) from the operator. When removing the cylinder, ensure the
cylinder is not tilted and the inside surface of the cylinder is not rubbing against
the piston.
NOTE:
Remove the spring cartridge prior to lifting the cylinder for SR operators.
9.
Remove the piston (11) with the drive rod (1) attached to it. Ensure that the drive
rod (1) is not rubbing against the cylinder plate (4) of the pedestal assembly (140)
when removing it.