background image

5

SECTION A

Assembly Instructions for Installing the

CF2600 and CF2650 Ceiling Fan with the Emerson

SR330 Remote Control or the SW350 Wall Control

1. Obtain the hanger ball/downrod assembly and

remove the hanger ball by loosening the setscrew
in the hanger ball until the ball falls freely down the
downrod (Figure 1A). Remove the pin from the
downrod, then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in Step 16.

2. Push the wiring harness connector (supplied with

the SW375 Receiver), the connector on the blue
wire (supplied with the SR330 or SW350 Control),
and the connector on the yellow uplight lead
(supplied with the fan) through the downrod until
they extend about 4” out of the pipe (Figure 2A).

3. Cut the harness wires approximately 3” from the

end of the downrod (Figure 2A). Strip insulation
1/2” from end of wires.

4. Position the motor housing and shade assembly in

the upper foam packing so that the top of the
motor is facing you.

5. Separate, untwist and unkink the three motor

leads.

6. Cut the white, blue and black wires about 3” above

the motor coupling (Figure 3A). Strip insulation
1/2” from end of the white and blue wires. Install a
wire connector on the black wire; this wire will not
be used. 

7. Using wiring connectors (supplied), connect the

white, blue and yellow wires from the downrod to
the white, blue and yellow wires from the fan motor
(Figure 4A and 6A). Wires must be connected
color-to-color.

8. Remove the wire connectors from the red wires

and the brown wires (Figure 4A).

9. Cap the red and the brown wires from the

reversing switch using a wire connector on each
wire (Figure 5A).

10. Using wiring connectors (supplied), connect the

red and brown wires from the downrod to the red
and brown wires from the fan motor (Figure 5A
and 6A). Wires must be connected color-to-color.

HANGER BALL

PIN

DOWNROD

SETSCREW

Figure 1A

YELLOW WIRE

WHITE
WIRE

BLACK WIRE

BLUE WIRE

INSULATE BLACK
WIRE USING WIRE
CONNECTOR

3"

Figure 3A

REMOVE WIRE CONNECTOR
FROM RED WIRES

CONNECT 
YELLOW WIRES

CONNECT 
WHITE WIRES

CONNECT BLUE WIRES

DOWNROD

REMOVE WIRE CONNECTOR
FROM BROWN WIRES

Figure 4A

DOWNROD

SLOT IN MOTOR
COUPLING

CAP BROWN AND RED
USING WIRE CONNECTORS

CONNECT
RED WIRES

CONNECT
BROWN WIRES

REVERSING SWITCH

Figure 5A

4"

YELLOW UPLIGHT LEAD

BLUE WIRE

WIRING
HARNESS

DOWNROD

CUT HERE

3"

Figure 2A

Summary of Contents for BP7251

Page 1: ... return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage Wh...

Page 2: ...y U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceili...

Page 3: ...insure that all steps have been completed and will be helpful in finding your place should you be interrupted 18 DOWNROD ROD ASSEMBLY 3 BLADE FLANGES ROD SUPPORT ASSEMBLY HANGER BALL DOWNROD ASSEMBLY YELLOW LEAD ASSEMBLY UPLIGHT LIGHT KIT PLATE ASSEMBLY FAN MOTOR HOUSING AND SHADE ASSEMBLY CEILING COVER LOOSE PARTS BAG HANGER BRACKET MOTOR COVER GLASS SHADE LIGHT KIT ADAPTER ASSEMBLY Installed Wir...

Page 4: ...ed Consult a qualified electrician if in doubt WARNING Electrical Requirements IMPORTANT INSTALLATION INFORMATION Your ceiling fan contains a built in uplight assembly in the motor housing The fan and uplight may be controlled using one of the two following methods 1 By an Emerson SR330 Remote Control or SW350 Wall Control 2 By any other Emerson Fan Light Controls or by Standard Wall Switches Beca...

Page 5: ...t 3 above the motor coupling Figure 3A Strip insulation 1 2 from end of the white and blue wires Install a wire connector on the black wire this wire will not be used 7 Using wiring connectors supplied connect the white blue and yellow wires from the downrod to the white blue and yellow wires from the fan motor Figure 4A and 6A Wires must be connected color to color 8 Remove the wire connectors fr...

Page 6: ... the motor All wires and wire connectors must be enclosed under the motor cover NOTE Lightly snug the knurled knob and make sure the wires and wire connectors are completely inside the motor coupling cover and not pinched between the motor coupling cover and the motor 15 Position the ceiling cover over the downrod Be sure the cover is oriented correctly with the large opening at the top Figure 9A ...

Page 7: ...ecessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 2 Figure 12A TOP OF HOUSING CANDELABRA BASE LAMP SOCKET Figure 10A 19 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to...

Page 8: ...the hole in the ceiling cover is clear of the downrod 29 Attach one blade assembly to the motor hub using two 10 32 x 5 8 oval head screws supplied Figure 17A Do not tighten completely at this time Install remaining blade assemblies in the same way Gently snug all flange screws to the motor hub working around the hub in a clockwise sequence Next securely tighten all flange screws again working in ...

Page 9: ...rs in the raised center portion of the plate assembly Do not pinch wires between the light kit plate assembly and the adapter assembly 33 Secure the light kit plate assembly to the light kit adapter assembly by threading three 5 32 32 x 3 16 phillips head screws supplied into the threaded holes in the adapter assembly Figure 20A 9 LIGHT KIT ADAPTER ASSEMBLY JUMPER ASSEMBLY SETSCREW COLLAR Figure 1...

Page 10: ...e 5 Separate untwist and unkink the three black white and blue motor wires then route the wires through the downrod 6 Using wiring connectors supplied connect the yellow uplight lead to the yellow wire from the downrod Figure 3B Fold the yellow wire into the slot in the motor coupling slide the downrod down the wires and seat the downrod in the motor coupling 7 Align the clevis pin holes in the do...

Page 11: ...HOUSING CANDELABRA BASE LAMP SOCKET Figure 6B DOWNROD PIN HANGER BALL CEILING COVER Figure 5B IMPORTANT A If you have installed an 18 or longer downrod and are planning to install the decorative support rods assembly proceed to INSTALLATION OF DECORATIVE SUPPORT RODS ASSEMBLY on page 14 After you have installed the decorative support rods assembly continue with the following installation procedure...

Page 12: ...hreaded studs and turn until studs protrude through the holes in the ceiling cover Figure 11B 18 Secure the ceiling cover in place by installing two lockwashers and two knurled knobs supplied Figure 11B Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod 19 Use three 10 32 x 3 8 pan head screws and fla...

Page 13: ...Figure 15B Connect the white wire from the plate assembly to the white wire form the motor shaft using a wire connector supplied NOTE When installing the light kit plate assembly position the wires and wire connectors in the raised center portion of the plate assembly Do not pinch wires between the light kit plate assembly and the adapter assembly 25 Secure the light kit plate assembly to the ligh...

Page 14: ...od support assembly and loosely engage the rod hook with one of the rings on the support assembly Figure 3 Then tighten the setscrew using the 5 64 setscrew 5 Engage the other two support rods in the same manner as above Loosen the setscrew and raise the rod support assembly until the support rods are taut and in line with the downrod Figure 4 Then securely tighten the setscrew using the 5 64 hex ...

Page 15: ...ire connections in the switch housing wire connections in the switch housing 2 Fan sounds noisy 1 Blades not attached to fan 1 Attach blades to fan before operating 2 Support rods loose 2 Tighten the barrels of the rod assemblies 3 Screws securing fan blade flanges to motor hub 3 Check to make sure the screws which attach are loose the fan flanges to the motor hub are tight WARNING Make sure main ...

Page 16: ...er Motor 761621 3 761621 17 761621 21 761621 23 761621 17 761621 21 24 Screw 8 Washerhead 4 25 Capacitor 9 mfd 762117 762117 762117 762117 762117 762117 26 Motor 762304 762304 762304 762304 762304 762304 27 Hub Motor 760601 760601 760601 760601 760601 760601 28 Flange Set Full set for one fan 762105 762105 1 762105 2 762105 3 762105 1 762105 2 29 Adapter Assembly Light Kit 762094 762094 762094 762...