U.L. Model No.: CF784

Safety Instructions

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK,

OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a.  Use this unit only in a manner intended by the

manufacturer.  If you have questions, contact the

manufacturer.

b.  Before servicing or cleaning unit, switch power off at

service panel and lock service panel disconnecting

means to prevent power from being switched on

accidentally. When the service disconnecting means

cannot be locked, securely fasten a warning device,

such as a tag, to the service panel.

                           

WARNING

!

Additional Safety Instructions for Installation

1.  To avoid possible shock, be sure electricity is turned off

at the fuse box before wiring, and do not operate fan

without blades.

2.  All wiring must be in accordance with the National

Electrical  Code  “ANSI/NFPA  70-2014”  and  Local

Electrical Codes. Use the National Electrical Code if

Local Codes do not exist. The ceiling fan must be

grounded as a precaution against possible electrical

shock.  Electrical  installation  should  be  made  or

approved by a licensed electrician.

3.  The outlet box and joist must be securely mounted and

capable of reliably supporting at least 50 pounds. Use

only U.L. outlet boxes listed as “Acceptable for Fan

Support of 22.7kg. (50 lbs.) or less”, and use the

mounting screws provided with the outlet box. Most

outlet boxes commonly used for support of light fixtures

are not acceptable for fan support and may need to be

replaced. Consult a qualified electrician if in doubt.

4.  The downrod furnished with the fan provides the

minimum recommended floor to fan blade clearance for

an 8 foot ceiling.

5.  The fan must be mounted with the fan blades at least

7 feet from the floor to prevent accidental contact with

the fan blades.

6.  Follow the recommended instructions for the proper

method of wiring your ceiling fan. If you do not know

enough about electrical wiring, have your fan installed by

a licensed electrician.

WARNING: 

To reduce the risk of electrical shock, this fan

must be installed with an isolating wall control/switch.

NOTE: 

This fan is suitable for use with solid-state speed

controls.

WARNING:

To avoid fire, shock or injury, do not use an

Emerson or any other brand of control not specifically

approved for this fan.

WARNING:

This product is designed to use only those

parts supplied with this product and/or any accessories

designated specifically for use this product by Emerson

Electric Co. Substitution of parts or accessories not

designated for use with this product by Emerson could

result in personal injury or property damage.

WARNING: 

To reduce the risk of personal injury, do not

bend the blade flange when installing the blade flanges,

balancing the blades or cleaning the fan. Do not insert

foreign objects in between rotating fan blades.

NOTE: 

All setscrews must be checked and re-tightened

where necessary before installation.

1.  Read your owner’s manual carefully and keep it for future

reference.

2.  Be careful of the fan and blades when cleaning, painting,

or working near the fan. Always turn off the power to the

ceiling fan before servicing.

3.  Do not put anything into the fan blades while they are

turning.

4.  Do not operate reversing switch until fan blades have

come to a complete stop.

SERIAL NUMBER:                                                                        DATE CODE:

The serial number of this fan can be found on the nameplate on top of the fan housing. The date code can be
found on the carton and on top of the fan housing, stamped in ink on a white label. You should record this data
above and keep it in a safe place for future use.

READ AND SAVE THESE INSTRUCTIONS

Table of Contents

Section                                                                                                  Page

Safety Instructions   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1. Unpacking Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
2. Electrical Requirements    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3. Ceiling Fan Assembly    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-11
4. How to Hang Your Ceiling Fan    . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
5. How to Wire Your Ceiling Fan   . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-15
6. Using Your Ceiling Fan  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
7. Maintenance   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Section                                                                                                  Page

8. Accessories   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
9. Energy Efficient Use of Ceiling Fans   . . . . . . . . . . . . . . . . . . . . . . . . .17
10. Repair Parts   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18-19
11. Trouble Shooting   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Ceiling Fan Limited Warranty   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Spanish   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
French   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49

Summary of Contents for Carrera CF784BS00

Page 1: ...al CF784BS00 Brushed Steel CF784GES00 Golden Espresso CF784ORB00 Oil Rubbed Bronze CF784SW00 Satin White Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Net Weight 28 4 Lbs Model Numbers Español página 25 Français page 49 ...

Page 2: ... installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed to use only those parts...

Page 3: ...eing lost If any parts are missing call 1 800 654 3545 for replacement parts before proceeding 1 2 Remove the fan motor assembly from the protective plastic bag Place the fan assembly into the lower styrofoam with the bottom of the motor facing up The upper styrofoam serves as a holder for the fan during the first stages of assembly PACKAGE CONTENTS 7 9 8 5 4 3 2 1 6 12 10 11 Part Description Quan...

Page 4: ...let box and box connectors must be of type required by the local code The minimum wire would be a 3 conductor 2 wire with ground of following size Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 2 Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit To reduce the risk of fire electric shock or personal in...

Page 5: ... the hub notch area over each of the five screws which is holding the shipping retainer to the motor assembly One by one unscrew each screw and discard screws and shipping retainer Figure 1 FLANGE GASKET BLADE FLANGE Figure 2 3 2 Verify that the flange gaskets are preinstalled onto the end of each of the blade flanges Figure 2 A spare flange gasket is supplied in the loose parts bag if required BL...

Page 6: ...URE FLANGE INTERLOCKING FEATURE Figure 5 3 5 NOTE Each blade flange assembly must have the flange gasket in place between each of the assemblies The blade flanges have an interlocking feature that must be fully engaged before tightening the screw Make sure all the flanges are properly engaged and then tighten the flange screws Figure 5 If one of the flanges does not seat properly on the motor hub ...

Page 7: ... SWITCH HOUSING ASSEMBLY SWITCH HOUSING ADAPTER Figure 6 Installation of Switch Housing Assembly for Manual Control 3 6 Remove and retain the three 8 32 x 12mm flat head screws from the switch housing plate Engage the connector of the switch housing assembly with the motor connector Figure 6 The two connectors are keyed and color coded and must be mated correctly color to color before they can be ...

Page 8: ...e 10 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 3 15 NOTE Do not loosen the screw holding the green ground wire SETSCREW LOOSENED HANGER BALL 4 5 DOWNROD PIN GREEN GROUND WIRE Figure 10 THREE 80 MOTOR LEADS UNTWISTED 4 5 DOWNROD Figure 11 It is critical that the clevis pin in the motor coupling is properly installed and the...

Page 9: ...gh the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed It is critical that the clevis pin in the motor coupling is properly installed Failure to verify that the pin is properly ins...

Page 10: ...ly installed in the motor coupler cover then slide the motor coupler cover on the downrod until it rests on the motor housing Be sure the motor coupler cover is oriented correctly Figure 14 CEILING COVER DOWNROD Figure 15 3 15 Place the ceiling cover over the downrod Be sure the ceiling cover is oriented correctly Figure 15 ...

Page 11: ...nd securely tighten the setscrew in the hanger ball NOTE A loose setscrew could create fan wobble It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling WARNING 3 Ceiling Fan Assembly continued HANGER BALL DOWNROD ASSEMBLY 6 to 9 INCHES Figure 17 3 17...

Page 12: ...or fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING 4 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 19 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan...

Page 13: ...insulation Securely connect wires with wire connectors supplied Figure 21 5 How to Wire Your Ceiling Fan To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING This product is designed to use only those p...

Page 14: ...ITE WIRES GREEN WIRES Figure 24 5 4 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and position the black black blue lead on the other side of the outlet box Figure 24 Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors excep...

Page 15: ...the ceiling cover and the ceiling WARNING 5 6 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 26 5 7 Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 26 Tighten the knurled knobs securely until the ceiling cover fits snugly against the cei...

Page 16: ...EVERSE SWITCH SWITCH HOUSING ASSEMBLY Figure 27 To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device WARNING 6 2 Check the operation of the fan by gently pulling on the pull chain switch Cut the 3 speed switch pull chain to a desired length optional Connect the die cast pendant supplied to the 3 speed switch pull chain by sliding the die cast...

Page 17: ...ve cleaning agents are not required and should be avoided to prevent damage to finish 7 Maintenance Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 ...

Page 18: ...18 U L Model No CF784 10 Repair Parts 1 4 3 16 2 22 17 21 8 7 13 10 PARTS BAG 7 4 10 11 13 9 6 5 8 12 15 14 18 19 20 11 9 9 5 6 ...

Page 19: ...ning 764687 CHM 764687 BLX 764687 BLX 764687 CHM 4 Threaded Studs 2 5 Lockwashers 2 6 Knurled Knobs 2 7 Pin Clevis 8 Clip Hairpin 9 Screw Flat Head 8 32 x 12mm 1 10 Screw Pan Head 1 4 20 x 14mm with Lockwasher 1 11 Screw Washer Head 10 24 x 10mm 21 12 Wire Connectors 3 13 Flange Gaskets 1 14 Die Cast Pendant and Coupler 1 set 15 Balancing Kit 1 16 Cover Ceiling 1 763785 BS 763785 GES 763785 ORB 76...

Page 20: ...housing 4 Check to make sure wire connectors in switch rattling housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF 5 Screws holding blades to flanges are 5 Tighten screws securely loose 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Tighten both setscrews securely in the motor excessively coupling 2 Setsc...

Page 21: ...21 emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF784 Notes ...

Page 22: ...Notes 22 U L Model No CF784 ...

Page 23: ...s limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returnin...

Page 24: ...Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EmErSON ElEctrIc cO 8100 W Florissant St louis mO 63136 Part No F40BP75010001 Form No BP7501 1 Revision 150827 U L Model No CF784 Printed in China 08 15 ...

Reviews: