background image

2

WARNING: 

To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1. Read your owner’s manual carefully and keep it for future reference.

2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting

means to prevent power from being switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a warning device, such as a tag, to the service panel.

3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to

the ceiling fan before servicing.

4. Do not put anything into the fan blades while they are turning.

5. Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan

without blades.

2. All wiring must satisfy National and Local Electrical Codes. Use the National Electrical Code if Local Codes do

not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical
installation should be made or approved by a licensed electrician.

3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use

only U.L. outlet boxes listed as acceptable for fan support, and use the mounting screws provided with the
outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified electrician if in doubt.

4. The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an

8 foot ceiling.

5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the

fan blades.

6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know

enough about electrical wiring, have your fan installed by a licensed electrician.

WARNING: 

To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically

approved for this fan.

WARNING:

This product is designed to use only those parts supplied with this product and/or any accessories

designated specifically for use this product by Emerson Company could result in personal injury or property
damage.

WARNING: 

To Reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges,

balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

WARNING

!

DATE CODE:

The date code of this fan may be found on

the box, stamped in ink on a white label.

You should record this data above and keep

it in a safe place for future use.

Summary of Contents for CF929BS

Page 1: ...n on the product with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not ...

Page 2: ...upporting at least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan b...

Page 3: ...ground of the following size 3 Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam p...

Page 4: ...ts on the motor housing Place the ceiling cover over the downrod Be sure both the ceiling cover and the coupler cover are oriented correctly Figure 3 5 Reinstall the hanger ball Figure 4 on the downrod as follows Route the motor leads through the downrod Position the pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball Pull ...

Page 5: ...nal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at ...

Page 6: ...RITY Figure 10 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING To avoid possible fire or shock do not pinch wires betwe...

Page 7: ...fferent frequencies In most cases you will not need to change the factory set frequency The frequency should only need to be changed for one of the following reasons a Multiple fans in one location that you wish to operate from one transmitter ALL fans should be set at the same frequency NOTE Your Emerson Remote Control is designed to operate from a distance up to 20 feet from the fan If you are o...

Page 8: ...r LOW buttons to operate your fan on high medium or low speed See Figure 14 2 To turn your fan off press the FAN OFF button 3 To change the airflow direction of the fan blades press the FOR REV button The direction the fan blades turn will change each time the FOR REV button is pressed 4 To set the level of light brightness press and hold the LIGHT DIMMER button The light brightness will continue ...

Page 9: ...3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Raise coupler cover and tighten the setscrew securely excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod assembly loose 3 Screws securing fan blade flanges to motor are 3 Check to be sure screws which attach the fan blade loose flanges to the motor are tight 4 Fan blade flanges not seated...

Page 10: ...ot use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or accessories not designated for use with this product by Emerson c...

Page 11: ...11 9 4 15 11 6 1 2 3 7 5 14 16 18 17 8 19 10 13 FAN OFF FOR REV LIGHT DIMMER HI MED LOW 12 Repair Parts ...

Page 12: ...t Assembly 762378 762378 18 Fluorescent Lamp 40 Watt 762379 762379 19 Receiver Dimmer Control 762380 762380 Owner s Manual BP7269 BP7269 Contact your nearest authorized Emerson fan dealer for replacement Fan Light Control Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER...

Reviews: