background image

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

1. Your ceiling fan is supplied with an Emerson

Fan/Light Control. Wire your ceiling fan in
accordance with the Owner’s Manual supplied with
the Fan/Light Control. After splices have been
made, carefully push splices up into the outlet box.

2. After completion of wiring, install the ceiling cover

as follows. Screw the two 1-1/4” threaded studs
(provided) into the tapped holes in the hanger
bracket.

6

How to Wire Your Ceiling Fan

CEILING COVER

LOCKWASHERS (2)

KNURLED KNOB

1-1/4"
THREADED STUD

Figure 11

4. Secure the ceiling cover in place by sliding

lockwashers over the threaded studs and installing
the two knurled knobs (supplied). (Figure 11.)
Tighten the knurled knobs securely until the ceiling
cover fits snugly against the ceiling and the hole in
the ceiling cover is clear of the downrod. Your fan
is now wired to be turned on and off from the fan
switch.

2.Carefully lift the fan and seat the hanger

ball/downrod assembly on the hanger bracket that
was just attached to the outlet box (Figure 10). Be
sure the groove in the ball is lined up with tab on
the hanger bracket (Figure 9).

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD ASSEMBLY

NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.

Figure 10

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

WARNING

!

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

WARNING

!

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

WARNING

!

3. Lift the ceiling cover up to the threaded studs and

turn until studs protrude through the holes in the
ceiling cover (Figure 11).

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.

WARNING

!

1. Securely attach the hanger bracket to the outlet

box using the two screws supplied with the outlet
box. (Figure 9.)

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

Figure 9

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician if in doubt.

WARNING

!

Summary of Contents for CF929BS

Page 1: ...n on the product with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not ...

Page 2: ...upporting at least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan b...

Page 3: ...ground of the following size 3 Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam p...

Page 4: ...ts on the motor housing Place the ceiling cover over the downrod Be sure both the ceiling cover and the coupler cover are oriented correctly Figure 3 5 Reinstall the hanger ball Figure 4 on the downrod as follows Route the motor leads through the downrod Position the pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball Pull ...

Page 5: ...nal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at ...

Page 6: ...RITY Figure 10 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING To avoid possible fire or shock do not pinch wires betwe...

Page 7: ...fferent frequencies In most cases you will not need to change the factory set frequency The frequency should only need to be changed for one of the following reasons a Multiple fans in one location that you wish to operate from one transmitter ALL fans should be set at the same frequency NOTE Your Emerson Remote Control is designed to operate from a distance up to 20 feet from the fan If you are o...

Page 8: ...r LOW buttons to operate your fan on high medium or low speed See Figure 14 2 To turn your fan off press the FAN OFF button 3 To change the airflow direction of the fan blades press the FOR REV button The direction the fan blades turn will change each time the FOR REV button is pressed 4 To set the level of light brightness press and hold the LIGHT DIMMER button The light brightness will continue ...

Page 9: ...3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Raise coupler cover and tighten the setscrew securely excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod assembly loose 3 Screws securing fan blade flanges to motor are 3 Check to be sure screws which attach the fan blade loose flanges to the motor are tight 4 Fan blade flanges not seated...

Page 10: ...ot use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or accessories not designated for use with this product by Emerson c...

Page 11: ...11 9 4 15 11 6 1 2 3 7 5 14 16 18 17 8 19 10 13 FAN OFF FOR REV LIGHT DIMMER HI MED LOW 12 Repair Parts ...

Page 12: ...t Assembly 762378 762378 18 Fluorescent Lamp 40 Watt 762379 762379 19 Receiver Dimmer Control 762380 762380 Owner s Manual BP7269 BP7269 Contact your nearest authorized Emerson fan dealer for replacement Fan Light Control Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER...

Reviews: