background image

19

emersonfans.com

Please contact 1-800-654-3545 for further assistance

ETL Model No.: CF995

What The Limited Warranty Covers:

This limited warranty is offered by Air Comfort Products division of Emerson Electric Co. (

"Emerson" "we"

or 

"us"

) located at the address stated below to the original

retail purchaser (

"you"

or 

"your"

) of an Emerson Air Comfort Ceiling Fan product (

"Emerson Ceiling Fan"

) and covers the motor and the other components and

accessories of the Emerson Ceiling Fan against all defects in workmanship and materials.

What The Period Of Coverage Is:

This limited warranty will cover the Emerson Ceiling Fan motor for the expected lifetime of your Emerson Ceiling Fan (when operated in accordance with your Owner's
Manual or other instructions provided by Emerson to you with the Emerson Ceiling Fan). All other components and accessories of the Emerson Ceiling Fan are covered
by this limited warranty for a period of one (1) year from its date of original retail purchase. ANY IMPLIED WARRANTY, INCLUDING WITHOUT LIMITATION, ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS AVAILABLE TO YOU UNDER THE LAWS OF YOUR STATE OR
PROVINCE SHALL COVER THE MOTOR FOR THE EXPECTED LIFETIME OF THE MOTOR (SUBJECT TO PROPER USE), AND FOR ONE YEAR WITH RESPECT TO
COMPONENTS AND ACCESSORIES.

No Other Express or Implied Warranty Applies:

THE LIMITED WARRANTIES PROVIDED ABOVE ARE THE SOLE AND EXCLUSIVE WARRANTIES PROVIDED BY EMERSON TO YOU FOR YOUR EMERSON CEILING
FAN, AND ARE IN LIEU OF ALL OTHER WARRANTIES, WRITTEN OR ORAL, EXPRESS OR IMPLIED, WHETHER ARISING BY OPERATION OF LAW OR OTHERWISE,
WHETHER OR NOT THE PURPOSE HAS BEEN DISCLOSED AND WHETHER OR NOT THE EMERSON CEILING FAN HAS BEEN SPECIFICALLY DESIGNED OR
MANUFACTURED FOR YOUR USE OR PURPOSE. EMERSON HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION,
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE FOR COMPONENTS AND ACCESSORIES AS OF THE EXPIRATION OF THE
ONE YEAR WARRANTY PERIOD FOR SUCH COMPONENTS AND ACCESSORIES. IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE FOR THE MOTOR PORTION OF THE EMERSON CEILING FAN ARE LIKEWISE DISCLAIMED BY EMERSON AT SUCH TIME THAT THE EXPECTED LIFETIME
OF THE EMERSON CEILING FAN UNDER NORMAL USAGE HAS BEEN REACHED.  EXCLUSIONS OR LIMITATIONS OF IMPLIED WARRANTIES MAY VARY FROM
STATE TO STATE AND PROVINCE TO PROVINCE SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.

What We Will Do To Correct Problems:

If during the one (1) year warranty period the motor or any component or accessory of your Emerson Ceiling Fan is defective in materials or workmanship, or if during
the expected lifetime of the Emerson Ceiling Fan (when used in accordance with the User Manual or other instructions) the motor is defective in materials or
workmanship, you must contact Emerson during the applicable warranty period. If the defect is covered by warranty, Emerson will repair or replace the defective
motor, component or other accessory at no charge to you. If repair of the motor, component or accessory is not practical or possible within a reasonable time and no
replacement Emerson Ceiling Fan can be provided, Emerson will refund to you the actual purchase price of your Emerson Ceiling Fan. We will ship the repaired or the
replacement Emerson Ceiling Fan to you at no charge, but you are responsible for all costs of removal and reinstallation of your Emerson Ceiling Fan.

How You Can Receive Warranty Service:

You must be the original retail purchaser and have proof of your purchase of the Emerson Ceiling Fan to obtain your remedy under this limited warranty. You can
return your Emerson Ceiling Fan to your place of purchase, or you can call Emerson Customer Service at 1-800-237-6511 to obtain a return authorization and service
identification tag. In order for us to confirm that your Emerson Ceiling Fan is still under warranty, please retain your receipt or other proof of purchase and have that
information readily available when returning your Emerson Ceiling Fan to your place of purchase, or upon calling Emerson Customer Service. If you call Emerson
Customer Service, prior to your call please be prepared to provide all model numbers shown on your Emerson Ceiling Fan. Once we have processed your return
authorization request, we will provide you with a postage paid return label which should be affixed to the Emerson Ceiling Fan package you ship to the address listed at
the end of this limited warranty. The return label will be sent to the mailing address you provide to us by phone. 

What Is Not Covered:

This limited warranty does not extend to and expressly excludes:

The glass globes and light bulbs of your Emerson Ceiling Fan, 

Loss or damage to the motor or any component or accessory caused by normal wear and tear, rather than due to defects in materials or workmanship,

Loss or damage resulting from conditions beyond our reasonable control, including without limitation, repairs not made at our factory or authorized service center,
use of parts or accessories not provided to you as part of this warranty by our factory or authorized service center, mishandling, unreasonable use, misuse, abuse,
modifications or other damage caused by you or a third party to your Emerson Ceiling Fan while not in our possession, 

Loss or damage resulting from improper installation, or other failure to comply with instructions in your Owner's Manual.

This limited warranty is deemed null and void upon the occurrence of either of the following events:

You cease to own the Emerson Ceiling Fan product, or

The Emerson Ceiling Fan is moved from its original point of installation.

This limited warranty is only valid within the 50 United States, the District of Columbia, and Canada. No other written or oral warranties apply, and no employee, agent,
dealer or other person is authorized to give any warranties on behalf of Air Comfort Products or Emerson Electric Co.

Limitation of Liability

REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE TO YOU UNDER THIS LIMITED WARRANTY. TO THE EXTENT PERMITTED BY
LAW, IN NO EVENT SHALL EMERSON OR ANY EMERSON AUTHORIZED DEALER BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL
DAMAGES, INCLUDING ANY ECONOMIC LOSS, WHETHER RESULTING FROM NONPERFORMANCE, USE, MISUSE OR INABILITY TO USE THE EMERSON CEILING
FAN OR FOR THE NEGLIGENCE OF EMERSON OR AN EMERSON AUTHORIZED DEALER. EMERSON SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN
PERFORMANCE AND IN NO EVENT, REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION (WHETHER BASED IN CONTRACT, INFRINGEMENT,
NEGLIGENCE, STRICT LIABILITY, OTHER TORT OR OTHERWISE), SHALL EMERSON'S OR ANY EMERSON AUTHORIZED AGENT'S LIABILITY TO YOU OR ANY
INDIVIDUAL USING THE EMERSON CEILING FAN EXCEED THE PRICE PAID BY THE ORIGINAL OWNER FOR THE EMERSON CEILING FAN. The term "consequential
damages" shall include, but not be limited to, loss of anticipated profits, business interruption, loss of use or revenue, cost of capital or loss or damage to property or
equipment.

How State and Provincial Law Relates To The Warranty:

Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you.
This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.

Emerson Air Comfort Ceiling Fan Limited Warranty

Summary of Contents for CF995BS00

Page 1: ...UCTIONS LACLEDE 62 Ceiling Fan Owner s Manual CF995BS00 Brushed Steel CF995VNB00 Vintage Steel Model Numbers Net Weight 34 6 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com ...

Page 2: ...an is suitable for use with solid state speed controls WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage WARNING To reduce the risk of ...

Page 3: ...or missing Call Toll Free for replacement parts 1 800 654 3545 WARNING 1 1 Check to see that you have received the following parts NOTE If you are uncertain of part description refer to exploded view illustration below NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing call 1 800 654 3545 for replacement parts before proceeding...

Page 4: ...onal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure el...

Page 5: ...DE FLANGE ASSEMBLY MOTOR HUB Figure 2 1 4 20 x 3 8 PAN HEAD SCREW WITH LOCKWASHER Figure 3 3 2 Loosely attach one blade flange assembly to the motor hub by securing the two 1 4 20 x 3 8 pan head screws with captive lockwasher Make sure the screws are loosely tightened for this step Figure 2 Repeat this procedure for other four blade assemblies To reduce the risk of personal injury do not bend the ...

Page 6: ...ened screw heads into the key hole slots Rotate the lower light fixture clockwise to engage both screws Tighten both screws and reinstall the previously removed screw to secure the fixture Figure 5 NOTE Be careful not to pinch any wires or connectors between the lower light fixture and the lower light adapter plate LOWER LIGHT FIXTURE WHITE CONNECTOR MOTOR WHITE CONNECTOR MOTOR BLACK CONNECTOR LOW...

Page 7: ...ver Rotate the cover clockwise to engage the screw heads Tighten the screws and reinstall the previously removed screw to secure the cover Figure 6 NOTE Be careful not to pinch any wires or connectors between the lower light cover and the lower light fixture STYROFOAM PARTIALLY ASSEMBLED CEILING FAN Figure 7 3 9 Turn the partially assembled ceiling fan right side up in preparation for final assemb...

Page 8: ...push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed MOTOR COUPLING DOWNROD MOTOR COUPLER COVER MOTOR COUPLER COVER GROMMET SETSCRE...

Page 9: ...n the setscrew in the hanger ball A loose setscrew could create fan wobble 3 16 The fan comes with black and white lead wires that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly and cut off excess lead wire and strip back insulation 1 2 inch from end of each lead wire It is critical that the pin in the hanger ball is pr...

Page 10: ...re to keep the rubber pad beneath each clamp to ensure proper clamping 3 19 Carefully secure the upper glass shade by gently tightening the four clamp screws Figure 14 GLASS SHADE CLAMP UPPER GLASS RUBBER PAD CLAMP SCREW Figure 14 10 ETL Model No CF995 3 Ceiling Fan Assembly continued ...

Page 11: ...ach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 16 NOTE Sloped Ceiling Installation The hanger bracket supplied with this fan can accommodate a 35 degree 8 12 pitch ceiling The hanger ball opening must be positioned to face up towards the peak of the ceiling Figure 19 Hanger bracket must seat firmly against outlet box If the outlet box is recessed ...

Page 12: ...D WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK FAN WIRE Figure 18 KNURLED KNOBS 2 LOCKWASHERS 2 THREADED STUDS 2 CEILING COVER Figure 19 To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover ...

Page 13: ...16 pan head screw removed previously and tighten all three screws to secure the lower light glass to the lower light assembly Install the finial nut finger tight Figure 22 8 32 x 5 16 PAN HEAD SCREW 3 FINIAL NUT LOWER GLASS SHADE Figure 22 LOWER LIGHT FIXTURE 13W E26 MEDIUM BASE CFL LIGHT BULBS 5 LOWER LIGHT FIXTURE SOCKETS 5 Figure 21 6 2 Lower Light Bulb Installation Install the five supplied 13...

Page 14: ...n the remote control transmitter to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the levers firmly up or down 2 The sixth switch marked ON and I is for dimming control of lights Set switch to ON to allow for dimming of the lights Set switch to I for no dimming of the lights such as for fluorescent bulbs 3 Reinstall the transmitter battery cover 4 Resto...

Page 15: ...tions about installation and operation of this ceiling fan 8 Programming the Receiver Operating Frequency High Speed Conditioning of Fan Control 8 1 IMPORTANT Ceiling fan blades MUST be installed before high speed conditioning can begin 1 Within 1 minute of restoring electricity to the ceiling fan push and hold the fan OFF button for 3 to 5 seconds to set the code in the receiver The ceiling fan l...

Page 16: ...he equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This...

Page 17: ...ve cleaning agents are not required and should be avoided to prevent damage to finish 12 Maintenance Model Numbers Key No Description CF995BS00 CF995VNB00 Hanger Ball Assembly 761655 97 761655 96 Consisting of 1 Hanger Bracket 2 Hanger Ball 3 Downrod 10 Parts Bag Containing 764458 CHRM 764458 BLOX 4 Pin Clevis 1 5 Clip Hairpin 1 6 Threaded Stud 8 32 x 1 1 4 2 7 Lockwasher External Tooth 8 2 8 Knur...

Page 18: ...xcessively coupling 2 Setscrew in hanger ball downrod 2 Tighten the setscrew in the hanger ball assembly is loose downrod assembly 3 Blades or flanges not tightly fastened to the fan 3 Check all blade and flange screws for tightness 4 Hanger bracket and or ceiling outlet box is not 4 Tighten the hanger bracket screws to the outlet box and or securely fastened secure outlet box WARNING Make sure ma...

Page 19: ...s limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returnin...

Page 20: ... Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74790000 Form No BP7479 Revision 131101 ETL Model No CF995 Printed in China 11 13 ...

Reviews: