20
ADVANCED USER GUIDE
IP66/Nema 4X variable speed drive
MENU 0 CORRESPONDENCE AND AUTOMATIC PARAMETER SETTING
CONTROL TECHNIQUES
3854 en - 03.2008 / b
2.3 - Parameter
25
to
35
• If
25
= OP.LP (0 or 1)
• If
25
= cL.LP (2) or SrvO (3)
2.4 - Parameters
36
to
80
(*) For preset configuration
05
= Pump, the addresses for
46
to
58
are different.
See section 2.2.9 - Internal setting.
Parameter
Name
Address
25
Operating mode
11.31
Parameter
Name
Address
26
Open loop mode select
5.14
• If
26
= r.run (0) or r.no (1) or r.FSt (3) or r.On (4)
or SqrE (5)
27
Not used
to
30
31
Current loop P gain
4.13
32
Current loop I gain
4.14
33
Not used
to
35
• If
26
= UtoF (2)
27
Not used
and
28
29
Boost
5.15
30
Dynamic V to F
5.13
31
Not used
to
35
Parameter
Name
Address
26
Encoder type
3.38
27
Encoder lines per revolution
3.34
28
Drive encoder filter
3.42
29
Speed loop P gain Kp1
3.10
30
Speed loop I gain Ki1
3.11
31
Current loop P gain
4.13
32
Current loop I gain
4.14
33
Ramp bypass
2.02
34
Not used
and
35
Parameter
Name
Address
36
Brake controller enable
12.41
37
Upper current threshold
12.42
38
Lower current threshold
12.43
39
Brake release frequency
12.44
40
Brake apply frequency
12.45
41
Brake apply/magnetisation delay
12.46
42
Post-brake release delay
12.47
43
Brake apply delay
12.48
44
Not used
12.49
45
Not used
46 *
Start/stop logic select
6.04
47 *
Secure disable select
8.10
48 *
ADIO3 mode
7.15
49 *
ADIO3 feature
7.33
50 *
DIO1 feature
8.41
51 *
Jog reference
1.05
52 *
Bipolar reference enable
1.10
53 *
Skip (critical speed)
1.29
54 *
Skip reference band
1.30
55 *
Deceleration ramp mode select
2.04
56 *
S ramp enable
2.06
57 *
Stop mode
6.01
58 *
Mains loss mode
6.03
59
Catch a spinning motor
6.09
60
Maximum switching frequency
5.18
61
Motor rated frequency
5.06
62
Number of motor poles
5.11
63
Autotune
5.12
64
Parameter cloning
11.42
65
Factory setting
11.43
66
User security code
11.30
67
Parameter displayed at power-up
11.22
68
Selection of load display
4.21
69
Speed display unit
5.34
70
Parameter scaling
11.21
71
Last trip
10.20
72
Penultimate trip
10.21
73
ADI1 input level
7.01
74
ADI2 input level
7.02
75
ADIO3 input or output level
7.03
76
Pre-offset reference
1.60
77
Pre-ramp reference
1.03
78
Current magnitude
4.01
79
Motor speed
5.04
80
DC bus voltage
5.05