Chapter 2
COMX-CAR-610 COM Express Carrier Board Installation and Use (6806800K26D)
21
Hardware Preparation and Installation
2.1
Environmental and Power Requirements
You must make sure that the board, when operated in your particular system configuration,
meets the environmental requirements specified below.
2.1.1
Environmental Requirements
Operating temperatures refer to the temperature of the air circulating around the board and
not to the component temperature.
Product Damage
High humidity and condensation on surfaces cause short circuits.
Do not operate the system outside the specified environmental limits. Make sure the
product is completely dry and there is no moisture on any surface before applying
power.
Table 2-1 Environmental Requirements
Environmental Factor
Operating
Non-Operating
Temperature
0 to +55°C
-40 to +85°C
Shock
20 g 11 ms sine or saw
Vibration
0.01g ^2/Hz at 5-500 Hz Random
Vibration
Air Flow
400 LFM at 0 to 55°C
Humidity
10-90% (non-condensing)