Page 51
Armature Current Programming - (JP9) Current Feedbac
k Range
STEP 7
otherwise go to
STEP 7a
Are you applying a Focus Model F3N2C or F3N2E ? If yes, then set jumper JP9 to the
letter that matches up most closely with your motors Armature Amp rating from the table below:
FOCUS Catalog
DC Output Current
JP9
Number
(A)
Jumper Position
2.7
No
Jumper
(1/4 – 2 HP)
5.5
A
F3N2C
6.4 B
F3N2E
7.5 C
10 D
go
Are you applying a Focus Model F3N5C
the
letter that matches up most closely with your motors Armature Amp rating from the table below:
otherwise go to
STEP 7
then
to STEP 8
STEP 7a
or F3N5E? If yes, then set jumper JP9 to
FOCUS Catalog
DC Output Current
JP9
Number
(A)
Jumper Position
6.6
No
Jumper
(3 – 5 HP)
13.8
A
F3N5C
16 B
F3N5E
18.75 C
25 D
Summary of Contents for Control Techniques Focus 3N
Page 7: ...Page vii ...
Page 52: ...Page 46 Tuning Adjus Optional tments Current Ref Gain Speed Ref Gain Zero Bias ...
Page 53: ...Page 47 ...
Page 54: ...Page 48 ...
Page 74: ......