13
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF790
If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
5.1
Position the supply wires to the left side of the outlet
box (Figure 20); position the fan wires to the right side.
Partially insert the remote control receiver (flat side up)
until one end rests on the hanger ball as shown in
Figure 20.
CAUTION: To reduce the risk of electrical shock,
disconnect the electrical supply circuit before
installing the fan or receiver.
5. How to Wire Your Ceiling Fan
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
WARNING
!
This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal injury
or property damage.
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring must
be in accordance with National and Local codes and
the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
WARNING
!
GREEN GROUND
WIRE FROM
HANGER BRACKET
GROUND
WIRE
GREEN GROUND
WIRE FROM
HANGER BALL
AC IN N
T
O
M
O
T
O
R
N
F
O
R
B
O
T
T
O
M
L
IG
H
T
T
O
M
O
T
O
R
L
AC IN L
Figure 21
AC IN N
AC IN L
F
O
R
B
O
T
T
O
M
L
IG
H
T
T
O
M
O
T
O
R
N
T
O
M
O
T
O
R
L
REMOTE
CONTROL
RECEIVER
HANGER
BALL
Figure 20
Refer to Figure 25 for complete wiring diagram.
Connect the receiver wires to the supply wires and
the fan motor wires as follows:
5.2
Connect the green grounding lead from the hanger
ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation).
Securely connect wires with wire connectors
(supplied) (Figure 21).
NOTE: Make all wiring connections using wire
connectors (supplied). Make sure that all
connections are tight, including ground, and that
no bare wire is visible at the wire connectors,
except for the ground wire.