20
ETL Model No.: CF790
7. Wall Control Installation
(Continued)
3-WAY WIRING DIAGRAM:
NEW CONSTRUCTION
NOTE: Retrofit 3-way installations are likely to
include two traveler wires between the two wall
boxes. In new construction, only one traveler wire Is
required (See Figure 32).
7.14
Screw the SW405 wall control into wall box using the
supplied screws. Leave the SW405 wall control in
“OFF” mode until fan installation is completed.
7.15
The SW405 wall control is supplied with a white, ivory,
and almond color switch covers. Choose the finish that
best suits your needs and snap the cover onto the
SW405 wall control (Figure 32).
7.16
Next, install the other SW405 wall control (sold
separately) into the wall box containing the load wire.
Connect the black wire of the SW405 wall control to the
traveler wire(s) already connected to the black wire (in
the other wall box). Secure with wire connectors
supplied.
7.17
Connect one black wire of the SW405 wall control to the
“load” (black) wire and secure with wire connector
supplied.
7.18
Connect one black wire of the SW405 wall control to
both remaining traveler wires in the wall box and secure
with wire connector supplied.
Figure 32
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
WARNING
!
STANDARD WIRING FOR EXISTING
3-WAY CONTROLS
EXISTING
WALL CONTROL
HOT
BLK
TRAVELER
WIRES
B
L
A
C
K
LOAD
SW405
FAN/LIGHT
WALL
CONTROL
BLK
B
L
A
C
K
LOAD
TRAVELER
WIRES
BLK
BLK
SW405
FAN/LIGHT
WALL
CONTROL
HOT
BLK
SECOND SW405
WALL CONTROL
PURCHASED
SEPARATELY
OFF
ON
....
OFF
ON
....
3-WAY WIRING DIAGRAM: RETROFIT