Ferrites installed on a standard cable
Figure 6-7:
Install ferrites on an armor-jacketed cable
1.
Make standard connections to the CSI 9420 terminal block and grounding screw.
2.
Slide the first of the three ferrites at the location on the cable approximately 1 in.
from the point where the cable enters the gland.
3.
Secure the ferrite using a wire tie, heat-shrink, or any other method approved for
your location.
4.
Slide the second and third ferrites onto the cable adjacent to the first, and secure
them in place with a wire tie or heat-shrink.
Accelerometer EMI and RFI considerations
MHM-97408, Rev 15
109
Summary of Contents for CSI 9420
Page 4: ......
Page 10: ...Revision numbers in AMS Device Manager Figure 1 2 Introduction 4 MHM 97408 Rev 15 ...
Page 60: ...PeakVue spectrum Figure 2 35 Configuration 54 MHM 97408 Rev 15 ...
Page 92: ...Setup 86 MHM 97408 Rev 15 ...
Page 134: ...Product certifications 128 MHM 97408 Rev 15 ...