6.1.5
Summary
To maximize immunity to EMI/RFI, consider the following when planning the installation of
the CSI 9420 and its accelerometers:
Required
•
Use ferrites to attenuate interference that couples into the accelerometer cable.
•
Ensure the installation conforms with all local codes and regulations.
Best practice
•
Use a shorter cable, if possible.
•
Consider running accelerometer cables in conductive conduit, grounded on both ends.
•
Avoid vertical cable runs because this geometry increases susceptibility to vertically polarized
causes of interference.