Ceiling Fan Trouble Shooting
TROUBLE
PROBABLE CAUSE
SUGGESTED REMEDY
1. Fan will not
1. Fuse or circuit breaker
1. Check main and branch
start.
blown.
circuit fuses or circuit breakers.
WARNING:
Make sure
main power is turned off.
2. Loose power line
2. Check line power connections
connections to the fan.
to fan.
3. Fan/Light remote control is OFF.
3. Turn ON Fan/Light remote control.
2. Fan sounds
1. Blades not attached to fan.
1. Attach blades to fan before
noisy.
operating.
2. Screws securing fan blades
2. Check to make sure the screws
to motor are loose.
which attach the blades to the
motor are tight.
WARNING:
Make sure main
power is turned off.
3. Fan wobbles
1. Screws securing fan blades
1. Check to be sure screws which
excessively.
to motor are loose.
attach the fan blade to the
motor are tight.
2. Fan blades are not seated
2. Check to be sure that the
properly.
screws securing the fan
blades seat firmly.
3. Fan blades out of balance.
3. Interchanging an adjacent (side
by-side) blade pair can
redistribute the weight and result
in smoother operation.
Or use supplied balancing kit to
balance blades.
4. Both lamps will
1. Loose electrical connectors.
1. Shut off the branch circuit
not illuminate.
electricity at the fuse box or
breaker panel and check the
receiver electrical connectors
for proper installation.
2. Remote control battery is weak. 2. Replace the AAA remote
batteries.
3. The lamps are burnt out.
3. Turn the electricity off and
replace the lamps with new
50W max. lamps.
4. Lamps turn on and then turn off. 4. The built in circuit breaker is
tripping, check that the lamps
are each 50W maximum.
CAUTION: Turn the lights off
before touching halogen lamps,
they are very hot and can burn
your fingers.
WARNING:
FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR
CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.
!
!
!
Light Kit Circuit Breaker
- Canada Only
In accordance with Federal Law, this
ceiling fan is equipped with a light kit
circuit breaker. Using halogen light bulbs
with greater than 50 watts rating will cause
the breaker to activate. If this occurs, shut
off the electricity to the ceiling fan and
check that the lamps are each 50W
maximum. The light kit circuit breaker will
automatically reset when the electricity is
turned off and then back on.