Damcos LPU: Troubleshooting Guide LPU
SM 8000-100-01 Ed 04
February 2017
64
Oil spillage, generally
Avoid starting motor until the correct level in tank has been ensured. After elimination of faults,
replenish tank with the correct oil for the specific system.
Oil in electronic connection box
Action:
•
At a large oil volume in electric connection box: Avoid starting the motor until having ensured
that the oil level in tank is OK.
•
Check pressure switch and solenoid valve for visible leakage, possibly by starting pump.
•
For LPU-S, leakage at pressure switch or solenoid valve will result in a pressure drop, so that the
LPU motor / pump restarts if this function is engaged.
•
Possible leakage from safety valve cannot be positively identified, until electronic connection
box has been dismounted.
•
Leakage from actuator, led through the position indicator can occur at leakage from actuator to
indicator. In special cases, oil may even be led through the power/bus cables from one LPU to the
next.
•
At leaking shaft seal on the electrical motor, the oil can run through motor and up in electronic
connection box.
•
After repair of defects, the tank is replenished with the correct oil for the specific system.
Oil spillage from breather valve
•
Oil spillage at emergency operation: see “Emergency operation by key giving oil spillage through
breather valve” on page 59 or “Emergency operation by hand pump giving oil spillage through
breather valve” on page 59.
•
Oil spillage during operation when motor is changing direction: Compressed air in actuator.
Actuator is to be de-aired.
Especially linear actuators (KC, KF and KFR) may have to be loosened from valve to be able to
close completely before de-airing of actuator.
•
Oil spillage when BRCF closes: Possibly air in actuator, actuator is to be de-aired. Breather valve
shall only be placed in BRCF or in LPU, not in both. Breather valve to be placed at highest possible
tank level. Too fast closing of actuator giving a high return pressure at closing letting oil out of
breather valve. Adjust closing speed to slower closing.
•
Oil spillage when KF or KFR closes: Possibly air in actuator, actuator is to be de-aired. Breather
valve must always be placed on top of KFR, and in LPU, where breather valve has to be placed at
highest possible tank level. Too fast closing of actuator giving a high return pressure at closing
letting oil out of breather valve. Adjust closing speed to slower closing.
•
Oil spillage at temperature rise in LPU-system: Oil tank overfilled or too great expansion at heat-
ing up, dependent on oil volume. At a large oil spillage due to heating up, an extended tank
should be used.
Summary of Contents for Damcos
Page 6: ...Service Manual Damcos LPU Table of Contents SM 8000 100 01 Ed 04 February 2017 6 ...
Page 8: ...Service Manual Damcos LPU Abbreviation and Denomination SM 8000 100 01 Ed 04 February 2017 8 ...
Page 11: ...Damcos LPU Safety Service Manual February 2017 SM 8000 100 01 Ed 04 11 ...
Page 12: ...Service Manual Damcos LPU Safety SM 8000 100 01 Ed 04 February 2017 12 ...
Page 22: ...Service Manual Damcos LPU LPU S Overview SM 8000 100 01 Ed 04 February 2017 22 ...
Page 26: ...Service Manual Damcos LPU LPU S Ex Overview SM 8000 100 01 Ed 04 February 2017 26 ...
Page 30: ...Service Manual Damcos LPU LPU S Ex ia Overview SM 8000 100 01 Ed 04 February 2017 30 ...
Page 34: ...Service Manual Damcos LPU LPU D Overview SM 8000 100 01 Ed 04 February 2017 34 ...
Page 38: ...Service Manual Damcos LPU LPU D Ex Overview SM 8000 100 01 Ed 04 February 2017 38 ...
Page 42: ...Service Manual Damcos LPU LPU D Ex ia Overview SM 8000 100 01 Ed 04 February 2017 42 ...
Page 44: ...Service Manual Damcos LPU Troubleshooting Guide LPU SM 8000 100 01 Ed 04 February 2017 44 ...
Page 92: ...Service Manual Damcos LPU Refill of Oil in LPU SM 8000 100 01 Ed 04 February 2017 92 ...
Page 96: ...Service Manual Damcos LPU Replace Pump in LPU SM 8000 100 01 Ed 04 February 2017 96 ...
Page 100: ...Service Manual Damcos LPU Replace release valve in LPU SM 8000 100 01 Ed 04 February 2017 100 ...
Page 110: ...Service Manual Damcos LPU Replace pressure switch SM 8000 100 01 Ed 04 February 2017 110 ...
Page 112: ...Service Manual Damcos LPU LPU Technical Data SM 8000 100 01 Ed 04 February 2017 112 ...
Page 118: ...Service Manual Damcos LPU LPU Technical Data SM 8000 100 01 Ed 04 February 2017 118 ...
Page 120: ...Service Manual Damcos LPU LPU Power Control System SM 8000 100 01 Ed 04 February 2017 120 ...
Page 128: ...Service Manual Damcos LPU LPU Power Control System SM 8000 100 01 Ed 04 February 2017 128 ...
Page 130: ...Service Manual Damcos LPU LPU P NET System SM 8000 100 01 Ed 04 February 2017 130 ...
Page 134: ...Service Manual Damcos LPU LPU P NET System SM 8000 100 01 Ed 04 February 2017 134 ...
Page 136: ...Service Manual Damcos LPU Hydraulic Hand Pump SM 8000 100 01 Ed 04 February 2017 136 ...
Page 140: ...Service Manual Damcos LPU Hydraulic Hand Pump SM 8000 100 01 Ed 04 February 2017 140 ...
Page 143: ......