background image

NOTE: If you are using an Emerson Light Fixture
with your fan, refer to the Light Fixture Owner’s
Manual for installation instructions.

8

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.

WARNING

!

GROUND

BLACK

TO AC
ELECTRICAL
SUPPLY

WHITE

GREEN

REMOTE CONTROL
RECEIVER

BLACK/WHITE

WHITE

BLUE

WHITE

BLACK

YELLOW

BLUE

WHITE

BLACK

ORANGE

Figure 14

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

WARNING

!

1-1/4"
THREADED
STUD

LOCKWASHERS (2)

CEILING COVER

KNURLED KNOB

Figure 16

3. Using wire connectors (supplied), make wiring

connections as follows (Figure 13 and 14):
a. Connect the green ground wires from the
hanger bracket and the hanger ball to the supply
ground wire (bare or green).
b. Connect the white fan wire and the white
supply wire to the white receiver wire (AC
IN/MOTOR N).
c. Connect the black fan wire to the black
receiver wire (TO MOTOR L).
d. Connect the black supply wire to the
black/white receiver wire (AC IN L).
e. Connect the blue fan wire to the blue receiver
wire (BOTTOM LIGHT).
f. Connect the orange fan wire to the yellow
receiver wire (UPPER LIGHT).
g. After connecting the wires, spread them apart
so that the green and white wires are on one side
of the outlet box and the black wire is on the
other side. Make sure that black antenna wire sits
on top of the receiver unit.

OUTLET BOX

BLACK SUPPLY WIRE

BLACK/WHITE RECEIVER WIRE

BLACK FAN WIRE

BLUE FAN WIRE

BLUE RECEIVER 
WIRE

ORANGE FAN WIRE

YELLOW RECEIVER WIRE

CEILING COVER

WHITE RECEIVER WIRE

WHITE FAN WIRE

WIRE CONNECTOR

RECEIVER

WHITE SUPPLY
WIRE

SUPPLY 
GROUND
WIRE (GREEN 
OR BARE)

HANGER BALL
GROUND WIRE
(GREEN)

HANGER BRACKET
GROUND WIRE
(GREEN)

HANGER BRACKET

BLACK RECEIVER WIRE

OPEN 

PORTION OF 

RECEIVER 

HERE

Figure 13

4. Insert the connected ends of the wires

up through the open side of the hanger
bracket and into the outlet box as
shown in Figure 15.

5. Screw two 1-1/4” threaded studs (sup-

plied with the ceiling fan) into the tapped
holes in the hanger bracket (Figure 15).

OUTLET BOX

RECEIVER

CEILING COVER

HANGER
BRACKET

1-1/4" 
THREADED
STUDS (2)

Figure 15

6. Slide the receiver up and over the hanger bracket.

Press the receiver against the ceiling, holding it in
place while installing the ceiling cover. Lift the
ceiling cover up to the threaded studs and turn until
studs protrude through the holes in the ceiling
cover (Figure 16).

7. Secure the ceiling cover in place by sliding lock-

washers over the threaded studs and installing the two
knurled knobs (supplied) (Figure 16). Tighten the
knurled knobs securely until the ceiling cover fits
snugly against the ceiling. Your fan is now wired to be
controlled using the remote control transmitter.

Summary of Contents for Designer Remote CF759AB03

Page 1: ...o return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage W...

Page 2: ...e not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 The fan must be installed on a level ceiling ...

Page 3: ...re provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembly your ceiling fan refer to section on proper method of wiring your fan page 7 If you feel you do not have enough wiring knowledge or experi ence have your fan installed by a licen...

Page 4: ...age door openers car alarms or security systems To remedy this situation simply change the combination code in your transmitter and receiver Preset Memory Feature Your Emerson remote control receiver is equipped with a preset memory feature If the electrical supply to the receiver is controlled through a wall switch when the switch is turned off the control will remember the light intensities and ...

Page 5: ... clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin ...

Page 6: ...al codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING WARNING WARNING NOTE Remove and discard the five shipping spacers and screws from the motor hub 11 Loosely attach one blade assembly to the motor hub using two M6 x 14 captive screws with lock washers Figure 9 Make sure the screws are NOT tightened Repeat this procedure for other four b...

Page 7: ...he outlet box is installed so that the mounting surface the bottom of the outlet box is level The receiver will be damaged resulting in an inoperable fan and a possible electrical fire Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall Failu...

Page 8: ...After connecting the wires spread them apart so that the green and white wires are on one side of the outlet box and the black wire is on the other side Make sure that black antenna wire sits on top of the receiver unit OUTLET BOX BLACK SUPPLY WIRE BLACK WHITE RECEIVER WIRE BLACK FAN WIRE BLUE FAN WIRE BLUE RECEIVER WIRE ORANGE FAN WIRE YELLOW RECEIVER WIRE CEILING COVER WHITE RECEIVER WIRE WHITE ...

Page 9: ...e electricity at the wall switch before installing or removing light bulbs on the ceiling fan or light fixture Figure 17 Operation IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the remote control Your remote control has full control of your fan and lights Figure 17 NOTE Prior to operation of the down light from the remote control make s...

Page 10: ... loose the fan flanges to the motor hub are tight 4 Wire connectors inside cup assembly 4 Check to make sure wire connectors in cup rattling assembly are not rattling against each other or against the interior wall of the cup assembly WARNING Make sure main power is turned OFF 5 Screws holding blades to flanges 5 Tighten screws securely are loose 3 Fan wobbles 1 Setscrew in motor coupling is loose...

Page 11: ...11 21 6 5 20 8 9 16 13 4 1 2 3 12 11 18 10 15 14 17 7 19 Repair Parts ...

Page 12: ...Screw M5 x 6 16 9 Washer Blade 16 10 Threaded Stud 2 11 Lockwasher 2 12 Knurled Knob 2 13 Canopy Ceiling 761620 761620 33 761620 3 761620 9 761620 25 761620 26 761620 29 14 Harness Reversing 763159 763159 763159 763159 763159 763159 763159 15 Switch Housing Assembly 763158 WW 763158 ORB 763158 AB 763158 OB 763158 BS 763158 WB 763158 AW 16 Cover Coupling 762463 15 762463 16 762463 4 762463 762463 8...

Reviews: