Installation
The table below represents the cycle time (operating time) per different Actuator sizes:
Table 6.
Operating Speed
Cycle time in seconds
Actuator
size
Spring-Return
Double-Acting
A-port
pressurized
Spring
stroke
A-port
pressurized
B-port
pressurized
F 12
0.4
0.4
0.4
0.4
F 25
0.5
0.4
0.5
0.4
F 40
0.6
0.5
0.6
0.5
F 65
0.7
0.5
0.6
0.6
F 100
0.8
0.6
0.8
0.7
F 150
1.0
0.8
0.9
0.8
F 200
1.3
0.9
1.0
1.0
F 350
1.9
1.3
1.4
1.5
F 600
3.2
1.9
2.2
2.2
F 950
4.6
3.2
3.9
3.6
F 1600
6.9
4.8
5.9
4.8
F 2500
9.0
6.3
7.8
7.9
F 4000
15.4
10.8
13.3
13.0
Operating time is average with actuator under load and solenoid valve fitted.
Test conditions:
1. Solenoid with flow capacity:
0.6 m
3
/hr
2. Pipe diameter:
6mm
3. Medium:
clean air
4. Supply pressure:
5.5 bar (80psi)
5. Load:
with average load
6.
Stroke:
90°
7. Temperature:
Room temperature
4.3.2
Ingress Protection (IP) rating
EL-O-Matic F actuators are IP66/IP67 rated. In case of IP66 or IP67 requirements, take
precautions that comply with the IP66/IP67 requirements to prevent moisture or dust from
entering the actuator through the open air exhaust port(s), either directly on the actuator
or at the exhaust ports of the connected solenoid valve.
We recommend to connect tubing to the exhaust(s) and lead this into a dry and dust free
area, or to use check valves in the exhaust.
Installation, Operation and Maintenance Manual
DOC.IOM.EF.EN Rev. 6
September 2015
9
Section 4: Installation