Disassembly
8.1
Removing End Caps
1.
For Double-acting actuators, do the following:
a.
Loosen the screws (10) of the end caps (2).
b.
Remove the o-ring (14) and "B" port seal (16). Discard these parts.
Figure 17
Double-Acting End Caps Removal
16
2
10
14
2
10
14
The above end caps (2) are for Actuator sizes 25, 40, 65 and 100.
End caps (2) for Actuator sizes 150 and larger will have flat end caps (see below).
2
2
Installation, Operation and Maintenance Manual
DOC.IOM.EF.EN Rev. 6
September 2015
25