Reassembly
Figure 28
Double-acting end cap assembly
16
2
10
14
2
10
14
The above end caps (2) are for Actuator sizes 25, 40, 65 and 100.
End caps (2) for Actuator sizes 150 and larger will have flat end caps (see below).
2
Table 15.
End cap Screw Torque
Actuator
size
Thread
Tool
Size
Torque (Nm)
Torque (lbf.ft)
Target Min.
Max. Target Min.
Max.
12
M4
Allen key
SW 3
1.1
0.8
1.3
0.8
0.6
1.0
25
M5
SW 4
2.0
1.6
3.0
1.5
1.2
2.2
40
M5
SW 4
2.0
1.6
3.0
1.5
1.2
2.2
65
M5
SW 4
2.0
1.6
3.0
1.5
1.2
2.2
100
M5
SW 4
2.0
1.6
3.0
1.5
1.2
2.2
150
M6
SW 5
3.3
2.6
5.1
2.4
1.9
3.8
200
M6
SW 5
3.3
2.6
5.1
2.4
1.9
3.8
350
M8
SW 6
8.4
6.7
12.2
6.2
4.9
9.0
600
M10
SW 8
15.3
12.2
24.8
11.3
9.0
18.3
950
1600
2500
4000
2
Installation, Operation and Maintenance Manual
DOC.IOM.EF.EN Rev. 6
September 2015
35
Section 9: Reassembly