Appendix
Table B-3.
NAMUR (VDE/VDI 3845) flanges
Flange
Metric
Torque (Nm)
Imperial
Torque (lbf.ft)
Thread
Min.
Max.
Thread
Min.
Max.
Solenoid flange screw threads
M5
2.0
3.0
10-24UNC
1.5
2.2
Top flange screw threads
M5
2.0
3.0
10-24UNC
1.5
2.2
Table B-4.
Limit stop screws and nuts
Actuator size
Thread
Bolt Wrench
Nut wrench
size (mm)
size (mm)
25
M 6
10
10
40
M 8
13
13
65
M 10
17 (16)
1
17 (16)
1
100
M 10
17 (16)
1
17 (16)
1
150
M 10
17 (16)
1
17 (16)
1
200
M 12
19 (18)
1
19 (18)
1
350
M 16
24
24
600
M 20
30
30
950
1600
2500
4000
Default dimension according DIN933 standard
Dimensions in brackets according ISO4017 standard
Actuator size 12 is not available with limit stops
Table B-5.
Recommended circlip pliers according DIN 5254 (or equal)
for shaft circlips
Actuator size
Pinion top diameter
Pliers according DIN 5254
F12
16 mm
0.630"
A1
F25 - F100
22 mm
0.866"
A2
F150 - F350
36 mm
1.417"
A3
F600
55 mm
2.165"
A3
46
September 2015
Installation, Operation and Maintenance Manual
DOC.IOM.EF.EN Rev. 6
Appendix