G e n e r a l   i n f o r m a t i o n :  

ESC Series Coils are for use with certain EMERSON products. 

Coil 

 

Voltage 

 

Approved 

Frequency 

 

Markings 

 

Devices 

Expansion  

Valves 

Solenoid Valves 

Oil management 

EX2 

CX2 

110RB 

200RB

 

200RH

 

200RC  240RA 

540RA 

M36 

OM3/4 

OM5 

OM3-02P* 

ESC-24VAC

 

24 VAC ±10 % 

(17 VA, 8 W)

 

50(60) Hz

 

,    

 

 ,      

 

 

 

 

 

 

 

 

 

 

 

1

 

ESC-230VAC

 

230 VAC ±10 % 

(17 VA, 8 W)

 

50(60) Hz

 

 

 

 

 

 

 

 

 

 

 

ESC-120VAC

 

120 VAC ±10 % 

(17 VA, 8 W)

 

50(60) Hz

 

 

 

 

 

 

 

 

 

 

 

ESC-M24VAC

 

24 VAC ±10% 

(25 VA, 16 W)

 

50(60) Hz

 

 

 

 

 

2

 

 

2

 

 

 

 

 

 

ESC-24VDC

 

24 VDC ±10 % 

(17 W)

 

--

 

,    

 

 ,      

 

 

 

 

 

 

 

 

 

 

ESC-W24VAC

 

24 VAC ±10 % 

(38 VA, 18 W)

 

50(60) Hz

 

 

 

 

 

 

 

 

 

 

 

NOTE 1:  

MOPD will decrease if the coils will be used at 60 Hz frequency. Also follow the operating instructions of the used devices.  

NOTE 2:  

1) OM3-02P used with R290 (A3). Installation only in a non-explosive environment. 

NOTE 3:  

2) Temperature impacts MOPD and ESC-M… coil use. Please refer to Technical Information. 

 

 

  S a f e t y   i n s t r u c t i o n s :  

• 

Read operating instructions thoroughly. Failure to comply can result in device failure, 

system damage or personal injury. 

• 

This product is intended for use by qualified personnel having the appropriate 

knowledge and skills like trained according to EN 13313 or a specific training for 

flammable refrigerants. 

• 

The coil should be fused in accordance with local codes. Electrically ground the valve 

body. 

• 

Do not exceed the specified maximum ratings for pressure, temperature, voltage and 

current. 

• 

Ensure that the system piping is grounded. 

• 

Before installation or service disconnect all voltages from system and device. 

• 

Observe and avoid mechanical damage of component housing. 

• 

Do not energize coil unless it is attached to the device. 

• 

Ensure that design, installation and operation comply with European and national 

standards/regulations. 

• 

Disposal: Electrical and electronic waste must NOT be disposed of with other 

commercial waste. Instead, it is the user responsibility to pass it to a designated 

collection point for the safe recycling of Waste Electrical and Electronic Equipment 

(WEEE directive 2012/19/EU). For further information, contact your local environmental 

recycling center. 

I n s t a l l a t i o n   o f   c o i l s :   ( F i g . 1 a , 1 b , 1 c )  

•  Mount O-ring with smaller diameter (1) over enclosing tube. 

•  Place coil over the enclosing tube and press it down by hand.  

•  Place the black retainer (2) on the upper visible end of the enclosing tube. The two slots 

of the retainer fit to stumps of ESC coil. (5)  

•  Insert O-ring with larger diameter (3) inside of the orange screw cap  

•  Press coil well down and tight the screw cap (4) over the retainer firsthand tight and then 

with torque 0.5 - 0.6 Nm in order to provide IP65 protection. Use spanner size 27 mm. 

 

E l e c t r i c a l   c o n n e c t i o n :  

• 

Entire electrical connections have to comply with local regulations. 

•  Before energizing the device, be sure that the source voltage and frequency matches 

that on the coil label. 

•  Ensure that the cables are mounted without tension; always leave the cable a bit loose. 

•  Ensure that cables are not mounted near sharp edges. 

•  Do not bend or mechanically stress the cable outlet, maintain a clearance of 20 mm to 

neighboring parts. 

•  Ensure, that the plug (with cable) is correctly placed and tighten. 

 

 

Standard plug and cable assembly (ASC-N…) 

Brown and blue color wires (BN & BL Fig. 2) to be connected to the power supply and 

yellow/green color wire to the ground. Connect pre-wired plug to the coil and tighten 

screw with 0.2 Nm. 

 

Plug and cable with electronic chopper module (DS2-N15) 

Polarity protected two wires to be connected to the power supply. 

 

Wiring with DIN Plug 

(Fig. 3)

 

Cable with three wires has to be connected to terminal 1 and 2 and   (ground) on the 

plug terminal box. Connect pre-wired DIN-plug to the coil and tighten screw with 0.2 Nm. 

S e r v i c e   /   M a i n t e n a n c e :  

• 

WARNING: ESC coils are intended for continuous-duty, which when energized for 

an extended period of time, it becomes hot. This is normal. Do not touch the coil 

during operation. Wait for coil temperature to cool down before attempting to 

dissemble it, or use gloves, failure to do so could lead to injury. 

• 

Disconnect electrical power before service. 

 

Dismantle of ESC: unscrew the screw cap (4) and pull the coil with retainer (2) out. 

Remove smaller O-ring.  

 

Replacement of ASC.../ ASC3… with ESC series: 

-

 

Dismantle ASC… by opening blue clip (Fig.4) 

-

 

Dismantle ASC3…: see Fig. 5. Remove smaller O-ring. 

•  To ensure proper function and protection, only O-rings approved for ESC coils may be 

used. Any existing O-rings must be replaced.

 

T e c h n i c a l   D a t a :    

Coil 

Inrush current 

(A) 

Holding current 

(A) 

ESC-24VAC 

2.23 

0.57 

ESC-230VAC 

0.22 

0.052 

ESC-120VAC 

0.48 

0.11 

ESC-24VDC 

0.72 

ESC-W24VAC 

2.7 

1.2 

ESC-M24VAC 

1.7 

1.05 

 

Supply voltage variation 

±10 % 

Ambient temperature range 

-40…+60 °C 

Protection class 

IP65  

(properly installed on enclosing tube 

with EMERSON offered Cables and plugs) 

Vibration resistance 

0.7 g 10 ... 200 Hz 

 

 

 

 

 

Summary of Contents for ESC Series

Page 1: ... press it down by hand Place the black retainer 2 on the upper visible end of the enclosing tube The two slots of the retainer fit to stumps of ESC coil 5 Insert O ring with larger diameter 3 inside of the orange screw cap Press coil well down and tight the screw cap 4 over the retainer firsthand tight and then with torque 0 5 0 6 Nm in order to provide IP65 protection Use spanner size 27 mm E l e...

Page 2: ...obere sichtbare Ende des Ankerrohres aufsetzen Die beiden Aussparungen des Halters passend zu den Überständen der ESC Spule ausrichten 5 O Ring mit größerem Durchmesser 3 in die orangefarbene Schraubkappe einlegen Die Spule gut nach unten drücken und die Schraubkappe 4 über der schwarzen Halterung zunächst handfest und dann mit einem Drehmoment von 0 5 0 6 Nm anziehen um die Schutzart IP65 zu erre...

Page 3: ... la partie visible du tube magnétique Les deux fentes de la bague viennent maintenir la bobine ESC 5 Insérer le joint torique avec le plus grand diamètre 3 à l intérieur bouchon orange à visser Presser fortement sur la bobine et serrer le bouchon à visser 4 sur la bague d abord à la main puis pour terminer avec un couple de 0 5 0 6 Nm afin d assurer la protection IP65 Utiliser une clé de 27 mm C o...

Page 4: ... la mano Coloque el retenedor negro 2 en la parte superior del vástago que queda visible Los dos rebajes en el retenedor coincidirán con los encajes de la bobina 5 Inserte la arandela de mayor diámetro en el interior de la tapa roscada naranja Presione firmemente la bobina hacia abajo y enrosque la tapa roscada naranja 4 sobre el retenedor primero con la mano y después con una llave de 27 mm par d...

Page 5: ... basso Posizionare il fermo nero 2 sull estremità superiore del tubo di chiusura facendo attenzione che le due fessure del fermo siano posizionate correttamente nella bobina ESC 5 Inserire l O ring grande 3 all interno del tappo a vite arancione Premere a fondo la bobina e serrare il tappo a vite 4 sul fermo inizialmente a mano e poi applicando una coppia di 0 5 0 6 Nm per garantire un grado di pr...

Page 6: ...тите черный фиксатор 2 на верхний видимый конец штока 2 паза фиксатора должны одеться на выступы катушки ESC 5 Вставьте кольцевую прокладку большего диаметра 3 внутрь оранжевой завинчивающейся крышки Надавите на катушку и плотно закрутите крышку 4 на фиксаторе сначала от руки затем с моментом 0 5 0 6 Нм чтобы обеспечить класс защиты IP65 Используйте гаечный ключ 27 мм Э л е к т р и ч е с к и е п о...

Page 7: ...mbH Pascalstrasse 65 I 52076 Aachen I Germany www climate emerson com en gb Date 18 01 2022 OI_ESC_A1_EN_DE_FR_ES_IT_RU_Rev03_866915 docx Fig Pис 1a Fig Pис 1b Fig Pис 1c Fig Pис 2 ASC N Fig Pис 3 DIN Plug Fig Pис 4 ASC Fig Pис 5 ASC3 W ...

Reviews: