7-6
Power Supply Block Diagram
L3821BLP
4A/125V
F601
4A/125V
LINE
FIL
TER
L601
AC
6
0
1
A
C
CORD
DEGA
USSING
COIL
DG691
CN691
PS691
BRIDGE
RECTIFIER
D605 - D608
HO
T
COLD
T601
6
4
2
1
4
3
IC601
ERR
OR
V
O
LT
A
G
E DET
Q601
Q602
LIMITER
SWITCHING
Q652
VR661
+B ADJ
Q696
RL601
MAIN CB
A
DG-ON-H
(T
O PIN75 OF IC301)
Q674
SWITCHING
P-ON-ON
P-ON-H
(T
O PIN4 OF IC301)
HOT CIRCUIT. BE CAREFUL.
1
2
FEED
BA
CK
SWITCHING
DG-ON-ON
+B
AL+32V
DEF +B
PR
O
TECT1
(T
O PIN61 OF IC301)
AU
D
IO
+
B
P-ON+8V
P-ON+5V
+8V
-CTRL
(T
O PIN28 OF IC301)
+5V
-CTRL
(T
O PIN32 OF IC301)
AL+5V
P-ON+1.2V
P-ON+1.2V
DTV
-H
(T
O PIN3 OF IC301)
AL+2.5V
P-ON+3.3V
AL+9V
P-ON+3.3V
P-ON+1.8V
+1.8V
-CTRL
(T
O PIN36 OF IC301)
+B
TP601
8
9
14
13
10
11
12
Q681
+8V
SWITCHING
Q682
Q901
Q902
Q646
Q645
+5V
SWITCHING
Q910
+3.3V
SWITCHING
Q383
+3.3V
SWITCHING
IC901
+5V REG.
IC903
+1.2V REG.
IC904
+1.2V REG.
IC910
+2.5V REG.
Q381
Q647
+1.8V
SWITCHING
Q673
Q672
+9V REG.
RESET
(T
O PIN5 OF IC301)
GND
TP300
Q382
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
For continued protection against risk of fire,
replace only with same type 4 A, 125V fuse.
CAUTION ! :
ATTENTION :
Utiliser un fusible de rechange de m
ê
me type de 4A, 125V.
4A/125V
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.