1 Introduction 

Condensing units manufactured by Copeland are equipped with fan(s). 
Various fan models are and were used. 
That is to say that today, it is possible to meet various fan(s) on the after-sales market. 
 

2 General 

information 

Condensing units can be equipped with 1, 2 or 4 fans. 
The complete fan consists of an external rotor motor with the fan blades permanently fixed to the rotor and the fan 
guard. The grid has 4 feet to mount it on the condenser. 
Fan motors are protected by a thermostatic switch. A single-pole bimetallic-element switch protects the motor 
against damage from: 

 

Motor overload 

 

Over-voltage and under-voltage 

 

Electrical and mechanical blockages 

 

Inadequate cooling. 

The fans protection is IP 54 and its insulation class is "F". 
Most fans can be equipped with a speed controller connected to the condensing pressure. 

Fans for Copeland Scroll and DWM Copeland semi-hermetic condensing units 

The fan is positioned in order to blow the air from the condenser to the compressor, so the compressor additional 
fan is not necessary any more. 
 

NOTE

: After connecting the condensing unit electrically, check the rotational direction. 

The fan must blow from 

the condenser to the compressor.

 

 

NOTE

: All fans presently used on condensing units are 

single-phase

 fans. 

3.1 Single-phase 

fans 

Single-phase fans are used since January 2003. 

3.1.1 Technical 

data 

As described in table 1, various fan models are used. 
 

Blade 

diameter

Power input

Voltage

Motor 

current

mm

W

V (±10%) / Ph / Hz

EBM

Rotomatika

A

Main

Auxilary

71

300

95

220 - 240 / 1 / 50

3 / 400

2.5 / 400

0.44

115

129

121

350

117

220 - 240 / 1 / 50

0.54

72

108

271

420

300

220 - 240 / 1 / 50

5 / 400

6.3 / 400

1.35

25

88

611

500

570

220 - 240 / 1 / 50

2.4

8.5

20.5

10 / 400

Winding resistance 

Ω 

(±10%), 25°C

Run capacitor

 µF / V

4 / 400

Fan model

Table 1: 

Technical data – single-phase fans

 

1/4

 

Summary of Contents for FANS

Page 1: ... 54 and its insulation class is F Most fans can be equipped with a speed controller connected to the condensing pressure 3 Fans for Copeland Scroll and DWM Copeland semi hermetic condensing units The fan is positioned in order to blow the air from the condenser to the compressor so the compressor additional fan is not necessary any more NOTE After connecting the condensing unit electrically check ...

Page 2: ... Y 3 50 1 10 0 65 500 550 3 50 0 52 220 240 1 50 3 6 220 240 380 420 Y 3 50 2 95 1 70 500 550 3 50 1 1 9 3 Winding resistance 5 400 8 400 16 400 25 400 20 60 51 6 2 6 2 18 6 54 7 57 3 172 10 325 24 20 Ω 10 25 C 102 104 3 218 6 574 37 270 420 280 610 500 630 Fan model 75 300 80 Run capacitor µF V 120 350 135 Table 2 Technical data three phase fans Old units were delivered with three phase fans as a...

Page 3: ... M21 L3 L2 L1 L3 L2 L1 A M22 A M22 Figure 2 230V 15 3 50 60 Hz Figure 3 Y 400V 15 3 50 60 Hz Y 500V 15 3 50 60 Hz Three phase fans can also be connected in single phase thanks to a run capacitor V2 Grey V2 Grey W1 Black W1 Black U2 Red U2 Red V1 Blue V1 Blue W2 Orange W2 Orange U1 Brown U1 Brown White White White White C1 C1 M21 F10 M Fan M Fan M21 F10 15 16 X1 N 14 13 L 12 11 10 9 L 8 Figure 4 Th...

Page 4: ...nding on the condensing unit model Current used fans model 121 or 271 are interchangeable with the previous models but the wiring has to be changed to single phase wiring The OMQ and OLQ have a low speed 910 rpm 6 pole single phase motor Today the condensers of the OM OMQ OL and OLQ units are equipped with single phase fan s The fan model is given in our Product Selection Catalogues and in Copelan...