2.2
Environmental Specifications
This section summarizes the environmental specifications for the device. For full details, refer to
the product data sheet
FB1100 Flow Computer
(D301781X012)
.
Table 2-1: Environmental Specifications
Specification
Range
Ambient Temperature
-40°C to +80 °C (-40 °F to +176 °F) - no battery, C1D1/C1D2
-40°C to +80 °C (-40°F to +176 °F) - lead acid battery, C1D1/C1D2
-40°C to +80 °C (-40 °F to +176 °F) - lithium battery, C1D1/C1D2
-40°C to +80 °C (-40 °F to +176 °F) - no battery, ATEX/IEC Ex db
-40°C to +80 °C (-40 °F to +176 °F) - no battery, ATEX/IEC Ex nA
Maximum Process Connection
Temperature
120 °C (248 °F)
Humidity
5% to 95% non-condensing
Vibration
2g over 10 to 150 Hz; 1g over 150 to 200 Hz
2.3
Required Tools
Certain tools and equipment are required for installing and servicing the flow computer.
Table 2-2: Required Tools
Tool
Use
Torque wrench
For bolting/mounting the flow computer
2.5 mm hexagonal wrench
For manipulating rotation set screw
3 mm hexagonal wrench
For screw for M4 x 0.7 end cap retaining clamp
(ATEX required)
9/16 in hexagonal wrench
For installing/removing ¾ in NPT conduit plugs
1 1/16 in combination wrench
For installing/removing ¾ in NPT to M20 thread
reducer (ATEX required)
#1 Phillips-head screwdriver
For screws on HMI module
#2 Phillips-head screwdriver
For screws on other modules and boards
1/8 inch flat-head screwdriver
For 5.08 mm pitch terminal block connections
Laptop PC running Field Tools with FBxConnect
configuration software
For software configuration