Emerson FB1100 Flow Computer Instruction Manual
D301752X012
August 2020
Installation
29
2.11.1
Connecting DC Power
DANGER
EXPLOSION HAZARD: Ensure the area in which you perform this operation is non-hazardous.
Performing this operation in a hazardous area could result in an explosion.
When power comes from an external DC supply, connect using the +DCIN and —DCIN terminals.
Use standard copper wire (#18 AWG minimum). The device supports 6V, 12V and 24V power
supplies. It accepts DC voltage from 5.7 to 30V; the amount of power required varies depending
upon the options used.
Figure 2-20: DC Power Connections
1
To External power supply
2.11.2
Connecting Battery Power
DANGER
EXPLOSION HAZARD: Ensure the area in which you perform this operation is non-hazardous.
Performing this operation in a hazardous area could result in an explosion.
When power comes from an internal battery pack, the battery pack plugs into one of two
connectors.