Emerson FB2100 Flow Computer Instruction Manual
D301783X012
March 2019
Installation
29
Rotating the Housing
To improve accessibility to the HMI module or to ease wiring, you can optionally rotate the
housing.
Note
Never rotate the housing more than 180 degrees from its original (as-shipped) position. Over-
rotation can break electronics within the unit.
Figure 2-20. Housing Rotation Set Screw (1 each side
)
1
Set Screw (one each side)
DANGER
EXPLOSION HAZARD: Never remove end cap(s) in a hazardous location. Removing end cap(s) in a
hazardous location could result in an explosion.
1.
Loosen the two housing rotation set screws.
2.
Rotate the housing no more than 180 degrees from its original (as-shipped) position.
3.
Re-tighten the two housing rotation set screws. Torque to 6 in-lbs. (0.7 N m).