Emerson FB2100 Flow Computer Instruction Manual
D301783X012
March 2019
Installation
33
Figure 2-22. DC Power Connections
1
To external DC power supply
Connecting Battery Power
DANGER
EXPLOSION HAZARD: Never remove end cap(s) in a hazardous location. Removing end cap(s) in a
hazardous location could result in an explosion.
When power comes from an internal battery pack, the battery pack plugs into one of two
connectors.
2.10.2.1
Installing the Main Battery Pack
If you purchased one of the battery/solar panel options, you need to install the main battery pack
before you place the device in service.
The device provides a battery cable with two pairs of battery connectors, enabling you to hot-swap
the battery pack in a non-hazardous location. You can use either pair of connectors when you
install the battery.
1.
Remove the battery pack from its packaging.
2.
Remove the plastic tabs covering the connectors on the battery pack.