D100341XUS2

Installation Guide
English – August 2012

Type 1301

www.fisherregulators.com

Introduction

This installation guide provides instructions for 

installation, startup, and adjustment.  To receive a copy 

of the instruction manual, contact your local Sales 

Office or view a copy at www.fisherregulators.com.  For 

further information refer to: Types 1301F and 1301G 

Instruction Manual (Form 1111, D100341X012).

P.E.D. Categories

This product may be used as a safety accessory 

with pressure equipment in the following Pressure 

Equipment Directive 97/23/EC categories.  It may 

also be used outside of the Pressure Equipment 

Directive using sound engineering practice (SEP) 

per table below.

Installation

!

WARNING

Only qualified personnel should install 

or service a regulator.  Regulators 

should be installed, operated, and 

maintained in accordance with 

international and applicable codes and 

regulations, and Fisher

®

 instructions.

If the regulator vents fluid or a leak 

develops in the system, it indicates that 

service is required.  Failure to take the 

regulator out of service immediately may 

create a hazardous condition.
Personal injury, equipment damage, or 

leakage due to escaping fluid or bursting 

of pressure-containing parts may result 

if this regulator is overpressured or 

is installed where service conditions 

could exceed the limits given in the 

Specifications section, or where 

conditions exceed any ratings of the 

adjacent piping or piping connections.
To avoid such injury or damage, 

provide pressure-relieving or 

pressure-limiting devices (as required 

by the appropriate code, regulation, 

or standard) to prevent service 

conditions from exceeding limits.
Additionally, physical damage to the 

regulator could result in personal injury 

and property damage due to escaping 

fluid.  To avoid such injury and damage, 

install the regulator in a safe location.

Clean out all pipelines before installation of the 

regulator and check to be sure the regulator has 

not been damaged or has collected foreign material 

during shipping.  For NPT bodies, apply pipe 

compound to the external pipe threads.  For flanged 

bodies, use suitable line gaskets and approved 

piping and bolting practices.  Install the regulator 

in any position desired, unless otherwise specified, 

but be sure flow through the body is in the direction 

indicated by the markings on the body.

PRODUCT SIZE

CATEGORY

FLUID TYPE

1/4 NPT

SEP

1

1. 

The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.

Specifications

Body Size and End Connection Styles

NPS 1/4, NPT screwed (one inlet and two or 

three outlet connections)

Maximum Allowable Inlet Pressure

(1)

414 bar / 6000 psig

Outlet Pressure Ranges

(1)

Type 1301F

: 0.69 to 5.2 bar / 10 to 75 psig, 

 

3.4 to 10.3 bar / 50 to 150 psig, and 6.9 to 15.5 

bar / 100 to 225 psig

Type 1301G

: 13.8 to 34.5 bar / 200 to 500 psig

Maximum Emergency Outlet Pressure

(1)

Type 1301F

: 17.2 bar / 250 psig

Type 1301G

: 37.9 bar / 550 psig

Proof Test Pressure

All Pressure Retaining Components have been 

proof tested per Directive 97/23/EC - Annex 1, 

Section 7.4.

Temperature Capabilities

(1)

Nylon (PA) Valve Disks: -29 to 82°C / 

 

-20 to 180°F

PTFE Valve Disks: -29 to 204°C / -20 to 400°F

Summary of Contents for Fisher 1301

Page 1: ...re relieving or pressure limiting devices as required by the appropriate code regulation or standard to prevent service conditions from exceeding limits Additionally physical damage to the regulator could result in personal injury and property damage due to escaping fluid To avoid such injury and damage install the regulator in a safe location Clean out all pipelines before installation of the reg...

Page 2: ...justment may be required to give the desired results With proper installation completed and relief valves properly adjusted slowly open the upstream and downstream shutoff valves Adjustment To change the outlet pressure loosen the locknut and turn the adjusting screw clockwise to increase outlet pressure or counterclockwise to decrease pressure Monitor the outlet pressure with a test gauge during ...

Page 3: ...CN7095_C 15 2 11 19 16 1 13 14 3 22 10 6 5 4 12 17 7 8 9 18 21 Figure 1 Type 1301F Regulator Figure 2 Type 1301G Regulator 20 40 S 6 0 0 0 P S I M A X I N L E T F I S H E R M AX OUTLET PSI U S A 20 6 0 0 0 M A X F I S H E M A X PSI U S A 40 S APPLY SEALANT S APPLY SEALANT S ...

Page 4: ... proper selection use and maintenance of any Emerson Process Management product remains solely with the purchaser Industrial Regulators Emerson Process Management Regulator Technologies Inc USA Headquarters McKinney Texas 75069 1872 USA Tel 1 800 558 5853 Outside U S 1 972 548 3574 Asia Pacific Shanghai 201206 China Tel 86 21 2892 9000 Europe Bologna 40013 Italy Tel 39 051 419 0611 Middle East and...

Reviews: