background image

Instruction Manual

D100279X012

262K Filter

September 2019

3

D

 If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this

instruction manual.

Using good piping practices, install the filter in the line with the flow in the direction of the arrow cast on the body. As
shown in figure 2, when the 262K filter is mounted in a horizontal line, the filter element must be pointed down. When
mounted in a vertical line, the filter element must also point down, with the flow passing from top to bottom.

Figure 3. Fisher 262K Filter

19B0172-A

Maintenance

Filter parts are subject to normal wear and must be inspected periodically and replaced as necessary. The frequency of
inspection and replacement depends upon the severity of service conditions and upon applicable codes and
government regulations.

  WARNING

Avoid personal injury or damage to property from sudden release of pressure or uncontrolled gas or other process fluid.
Before starting disassembly, carefully release all pressures. Use a gauge to monitor pressure while releasing it.

Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.

Summary of Contents for Fisher 262K

Page 1: ...ions and warnings If you have any questions about these instructions contact your Emerson sales office before proceeding Product Description The 262K filter is designed to remove dirt scale and other solid substances from the air supply to actuators and instruments The 262K filter is available with a cast iron Style B or stainless steel body Style SSB with NPT screwed connections See table 1 for t...

Page 2: ...nd maintenance procedures performed by unqualified personnel may result in unsafe operation This condition may result in personal injury or equipment damage Use qualified personnel when installing operating and maintaining this filter If a leak develops in the system the escaping gas may accumulate and become a fire or explosion hazard Immediately call qualified service personnel in case of troubl...

Page 3: ... down with the flow passing from top to bottom Figure 3 Fisher 262K Filter 19B0172 A Maintenance Filter parts are subject to normal wear and must be inspected periodically and replaced as necessary The frequency of inspection and replacement depends upon the severity of service conditions and upon applicable codes and government regulations WARNING Avoid personal injury or damage to property from ...

Page 4: ...d Arab Emirates Singapore 128461 Singapore www Fisher com The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability All sales are governed by our terms and con...

Reviews: