Instruction Manual
D100279X012
262K Filter
September 2019
3
D
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this
instruction manual.
Using good piping practices, install the filter in the line with the flow in the direction of the arrow cast on the body. As
shown in figure 2, when the 262K filter is mounted in a horizontal line, the filter element must be pointed down. When
mounted in a vertical line, the filter element must also point down, with the flow passing from top to bottom.
Figure 3. Fisher 262K Filter
19B0172-A
Maintenance
Filter parts are subject to normal wear and must be inspected periodically and replaced as necessary. The frequency of
inspection and replacement depends upon the severity of service conditions and upon applicable codes and
government regulations.
WARNING
Avoid personal injury or damage to property from sudden release of pressure or uncontrolled gas or other process fluid.
Before starting disassembly, carefully release all pressures. Use a gauge to monitor pressure while releasing it.
Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.