Instruction Manual
D101728X012
3710 and 3720 Positioners
September 2017
10
IECEx
Conditions of Certification
Intrinsically Safe
WARNING
Substitution of components may impair intrinsic safety.
-40
_
C ≤ Ta ≤ +82
_
C; T6 (Ta ≤ +47
_
C); T5 (Ta ≤ +62
_
C); T4 (Ta ≤ +82
_
C)
Entity Parameters: Ui
=
30 V, li = 150 mA, Pi = 1.25 W, Ci = 0 nF, Li = 0 mH
Flameproof
WARNING
Disconnect power before opening.
-40
_
C ≤ Ta ≤ +82
_
C; T5 (Ta ≤ +82
_
C)
Type n
WARNING
Disconnect power before opening.
-40
_
C ≤ Ta ≤ +82
_
C; T6 (Ta ≤ +82
_
C)
Refer to table 8 for approval information.
Table 8. Hazardous Area Classifications for Fisher 3722 Converter
—IECEx
Certification
Certification Obtained
Entity Rating
Temperature Code
IECEx
Intrinsically Safe
Gas
Ex ia IIC T4/T5/T6 Ga
Ui = 30 VDC
Ii = 150 mA
Pi = 1.25 W
Ci = 0 nF
Li = 0 mH
T4 (Tamb ≤
82
°
C)
T5 (Tamb ≤
62
°
C)
T6 (Tamb ≤
47
°
C)
Flameproof
Gas
Ex d IIC T5 Gb
- - -
T5 (Tamb ≤
82
°
C)
Type n
Gas
Ex nA IIC T6 Gc
- - -
T6 (Tamb ≤
82
°
C)
1. These hazardous area classification also apply to 3720 positioners.