background image

APPLY LuBRICAnT(1)
L1 = AnTI-SEIZE COMPOunD
L2 = MuLTI-PuRPOSE POLYTETRAfLuOROETHYLEnE (PTfE) LuBRICAnT
nOTE: KEY 31 OnLY uSED On unITS WITH CSA APPROVAL.

T80573

1. Lubricants must be selected such that they meet the temperature requirements.

 3

L2

31

 8

L1

26

 1

10

14

25

15

23

 5

22

16

L1

L2

12

 6

 7

 4

13

11

L2

 2

Figure 1.

 Type HSR Regulator Assembly (continued)

Type HSR

Facebook.com/EmersonAutomationSolutions

LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation

Webadmin.Regulators@emerson.com

Emerson Automation Solutions

For further information on the current 

PED revision see Bulletin: 

D103053X012

or scan the QR code.

Fisher.com

Americas

 

McKinney, Texas 75070 USA 

T   +1 800 558 5853 

+1 972 548 3574

Europe

 

Bologna 40013, Italy 

T  +39 051 419 0611

Asia Pacific

 

Singapore 128461, Singapore 

T  +65 6777 8211

Middle East and Africa 

Dubai, United Arab Emirates 

T  +971 4 811 8100

D103074X014 © 2006, 2019 Emerson Process Management Regulator 

Technologies, Inc. All rights reserved. 02/19. 

The Emerson logo is a trademark and service mark of Emerson 

Electric Co. All other marks are the property of their prospective owners. 

Fisher™ is a mark owned by Fisher Controls International LLC, a

 

business of Emerson Automation Solutions.
The contents of this publication are presented for information purposes 

only, and while effort has been made to ensure their accuracy, they are 

not to be construed as warranties or guarantees, express or implied, 

regarding the products or services described herein or their use or 

applicability. All sales are governed by our terms and conditions, which 

are available on request. We reserve the right to modify or improve the 

designs or specifications of our products at any time without notice.

Emerson Process Management Regulator Technologies, Inc does not 

assume responsibility for the selection, use or maintenance of any 

product. Responsibility for proper selection, use and maintenance of any 

Emerson Process Management Regulator Technologies, Inc. product 

remains solely with the purchaser.

VCIGD-11698-EN.indd   4

2/22/2019   7:46:26 PM

Summary of Contents for Fisher HSR Series

Page 1: ...pment damage or leakage due to escaping gas or bursting of pressure containing parts might result if these regulators are overpressured or installed where service conditions could exceed the limits for which the regulators were designed or where conditions exceed any ratings of the adjacent piping or piping connections To avoid such injury or damage provide pressure relieving or pressure limiting ...

Page 2: ...foreign matter which may have accumulated in the regulator body or in the pipeline Apply pipe compound to the male threads of the pipeline and install the regulator so that the flow is in the direction of the arrow cast on the side of the body The diaphragm actuator assembly can be rotated to any position relative to the body in 90 increments Remove the two cap screws that hold the body to the act...

Page 3: ...anges outlet pressure range Spring color mbar In w c 10 to 15 4 to 6 Orange 15 to 20 6 to 8 Yellow 20 to 25 8 to 10 Black 25 to 31 10 to 12 5 Silver 31 to 50 12 5 to 20 Gray 50 to 87 20 to 35 Pink 0 09 to 0 15 bar 1 25 to 2 2 psig Light Blue T80573 Key Description 13 Lower Spring Seat 14 Relief Spring Retainer 15 Body 16 O ring 17 Cap Screw 22 Orifice 23 Disk 25 Spring 26 Adjusting Screw 27 Inform...

Page 4: ...ment Regulator Technologies Inc All rights reserved 02 19 The Emerson logo is a trademark and service mark of Emerson Electric Co All other marks are the property of their prospective owners Fisher is a mark owned by Fisher Controls International LLC a business of Emerson Automation Solutions The contents of this publication are presented for information purposes only and while effort has been mad...

Reviews: